Port-A-Cath Tray, Inlcudes: Single-Lumen Standard Portal, Polysulfone/Titanium, 28x14.6x11.4mm, PolyFlow Polyurethane Catheter, 7.8FR, Straight Needle, Blunt Needle, Vein Pick, 18G Introducer Needle, 8.5FR, J-Guidewire, 90 Needle, Gripper Plus Safety N
Part Number Smiths Medical 21-4455-24
SKU Number CIA8069275
Sell Unit EACH
Ships Within Special Order
List Price $1,052.17
Enter a valid quantity
Product Description

Smiths Medical 21-4455-24 - Port-A-Cath Tray, Inlcudes: Single-Lumen Standard Portal, Polysulfone/Titanium, 28x14.6x11.4mm, PolyFlow Polyurethane Catheter, 7.8FR, Straight Needle, Blunt Needle, Vein Pick, 18G Introducer Needle, 8.5FR, J-Guidewire, 90 Needle, Gripper Plus Safety N

The Smiths Medical 21-4455-24 Port-A-Cath Tray is a comprehensive implantable vascular access tray designed for clinicians who require a reliable single-lumen port system for long-term infusion therapy. The tray includes a single-lumen standard portal made with polysulfone and titanium, measuring 28 x 14.6 x 11.4 mm, along with a 7.8FR PolyFlow polyurethane catheter and essential placement components for procedural efficiency.

Built for controlled vascular access, this Port-A-Cath tray supports medication delivery, fluid administration, blood sampling, and other clinically appropriate infusion applications when used by trained healthcare professionals. Its organized tray format helps reduce preparation time, supports procedural consistency, and ensures key components are available at the point of care.

Key Benefits

  • Complete Port-A-Cath tray designed for single-lumen vascular access procedures
  • Includes standard portal with polysulfone and titanium construction for dependable implanted access
  • 7.8FR polyurethane catheter supports reliable infusion performance in suitable clinical applications
  • Tray includes straight needle, blunt needle, vein pick, introducer needle, guidewire, 90 Degree needle, and Gripper Plus safety needle components
  • Organized procedural configuration helps improve workflow and reduce the need to source separate components
  • Designed for use in professional medical environments requiring long-term venous access solutions

Compatibility and Applications

The Smiths Medical 21-4455-24 Port-A-Cath Tray is intended for use in clinical settings where implantable vascular access is required. It is commonly selected for patients who may need repeated or long-term intravenous therapies, including infusion treatments, medication administration, hydration, blood draws, and other physician-directed vascular access applications.

The tray is suitable for use by trained physicians and vascular access teams familiar with implantable port placement techniques. Compatibility should always be confirmed against the facility protocol, patient condition, treatment plan, and applicable product instructions before use.

Usage Guidelines

This product should be used only by qualified healthcare professionals trained in implantable port placement and vascular access procedures. Before opening the tray, verify the product number, packaging integrity, expiration date, and all required components. The procedure should be performed using aseptic technique and in accordance with institutional guidelines.

Clinicians should follow the manufacturers instructions for placement, flushing, access, maintenance, and removal. Proper catheter positioning, secure port placement, and careful confirmation of function are essential to support safe and effective use. The device should not be used if the packaging is damaged, opened, or compromised.

Certifications and Safety Standards

The Smiths Medical 21-4455-24 Port-A-Cath Tray is manufactured for professional healthcare use and should be handled according to applicable medical device standards, facility policies, and manufacturer instructions. Sterility, single-use requirements, and procedural precautions must be followed as indicated on the product labeling.

Healthcare providers should ensure that use of this product aligns with relevant clinical protocols, infection prevention standards, vascular access guidelines, and any applicable regulatory requirements for implantable infusion devices.

Comparison with Competitors

Compared with sourcing port placement components individually, the Smiths Medical 21-4455-24 Port-A-Cath Tray offers a more procedure-ready configuration by combining the portal, catheter, access needles, introducer needle, guidewire, and support components in one organized tray. This can help streamline preparation and improve consistency in busy procedural settings.

In comparison with generic vascular access kits, this tray is designed around the Port-A-Cath system and includes components selected for compatibility with the included single-lumen standard portal and 7.8FR polyurethane catheter. Facilities that prioritize standardized supplies, dependable brand recognition, and efficient tray setup may find this configuration practical for long-term vascular access procedures.

Typical User Profile and Application Scenarios

This product is typically used by vascular surgeons, interventional radiologists, oncologists, infusion therapy teams, and trained hospital clinicians involved in implantable port placement. It is commonly used in hospitals, outpatient surgery centers, interventional suites, oncology care settings, and specialty infusion environments.

Typical application scenarios include long-term therapy planning, repeated intravenous medication delivery, infusion access for complex treatment schedules, and cases where peripheral access may be difficult or clinically unsuitable. Patient selection and device use should always be determined by the responsible healthcare provider.

Best Practices for Use and Maintenance

Before use, confirm that the selected port and catheter size are appropriate for the patient and intended therapy. Maintain strict sterile technique throughout placement and follow institutional protocols for skin preparation, device insertion, catheter confirmation, and dressing application.

After implantation, port access and maintenance should be performed by trained personnel using approved non-coring access needles and proper flushing protocols. Routine monitoring should include assessment for signs of infection, occlusion, leakage, discomfort, swelling, or device malfunction. Any concerns should be escalated according to facility policy and clinical judgment.

Regulatory and Safety Information

The Smiths Medical 21-4455-24 Port-A-Cath Tray is a medical device intended for professional use in appropriate healthcare environments. It should be used only according to the manufacturers labeling, applicable clinical standards, and the direction of licensed medical professionals.

Do not reuse, resterilize, or use the device outside its intended clinical application unless specifically permitted by the manufacturers instructions. Improper placement, handling, access, or maintenance may increase the risk of complications, including infection, thrombosis, catheter occlusion, extravasation, migration, or device failure.

How to Order

Select the Smiths Medical 21-4455-24 Port-A-Cath Tray, Inlcudes: Single-Lumen Standard Portal, Polysulfone/Titanium, 28x14.6x11.4mm, PolyFlow Polyurethane Catheter, 7.8FR, Straight Needle, Blunt Needle, Vein Pick, 18G Introducer Needle, 8.5FR, J-Guidewire, 90 Degree Needle, Gripper Plus Safety N and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.