-
Catheters (6,800+)
- Angiocatheters (50+)
- Closed System Catheters (300+)
- External Catheters (620+)
- Hydrophilic Catheters (140+)
- IV Catheters (1,200+)
- Non-Hydrophilic (20+)
- Plastic Catheters (200+)
- Rubber Catheters (700+)
- Silicone Catheters (770+)
- Ureteral Catheters (100+)
- Urethral Catheters (450+)
- Venous Catheters (240+)
-
Coronavirus (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (20,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Custom Kits
- Dental (14,000+)
- Gloves (8,000+)
-
Gynecology & Urology (1,000+)
- Bed Side Drainage Bags (350+)
- Circumcision (150+)
- Cord Clamps and Clippers (60+)
- Disposable Vaginal Specula (60+)
- Enema Bags (30+)
- External Catheters (620+)
- Foley Catheters and Trays (1,200+)
- Identification (1100+)
- Leg Bag Accessories (10+)
- Leg Bags (280+)
- Reusable Vaginal Specula (900+)
- Specimen Collection (200+)
- Tubing & Connectors (17,000+)
- Urinals / Bed Pans (1,300+)
- Urine Collectors (60+)
- Urological Irrigation Products (10+)
- Vaginal Specula Illumination (2+)
- Systems (11,000+)
- Hygiene (1,000+)
- Incontinence (1,000+)
-
Infection Control (2,500+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Iodine (460+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Infusion All (2,000+)
- IV Bags - Empty (300+)
- IV Bags - Filled (100+)
- Masks (3,800+)
-
Medical Apparel (23,000+)
- Arm Sleeves (240+)
- Beard Covers (20+)
- Bouffant Caps (200+)
- Compression Socks (80+)
- Coveralls (500+)
- Disposables (100+)
- Isolation Gowns (360+)
- Lab Coats (2,200+)
- Lab Jackets (300+)
- Patient Gowns (300+)
- Procedural Gowns (230+)
- Scrubs (20,000+)
- Shoe Covers (270+)
- Surgeon Caps (40+)
- Surgical Gowns (70+)
- Surgical Hoods (20+)
- Surgical Masks (330+)
- Ostomy (400+)
-
PPE (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (23,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Respiratory (500+)
- Sanitizer (600+)
- Surgical Supplies (14,000+)
- Sutures (7,500+)
- Syringes & Needles (14,000+)
-
Wound Care (5,000+)
- ABD Pads (100+)
- Adhesive Bandages (650+)
- Advanced Wound Care (400+)
- Applicators (6,700+)
- Burn care (240+)
- Dressings (7,500+)
- Elastic Bandages (1,600+)
- Gauze (3,300+)
- Ice / Heat Packs (280+)
- Medical Tape (820+)
- Non-Adhering Dressings (100+)
- Ointment & Solutions (450+)
- Self-Adherent Wraps (200+)
- Sponges (2,400+)
- Staple & Suture Removal (1,500+)
- Tegaderm (450+)
- Transparent Dressing (800+)
- Wound Care Prep (120+)
- Wound Cleansers (100+)
- Sales & Deals (100+)
- 3M (4,200+)
- Alaris Medical (600+)
- Amsino International (550+)
- Avanos Medical (40+)
- B Braun (1,500+)
- Baxter (750+)
- BD (2,800+)
- BSN Medical (2,000+)
- Cables & Sensors (3,200+)
- C.R. Bard (4,200+)
- Cardinal Health (6,800+)
- CareFusion (2,100+)
- ConMed (1,500+)
- Cook Medical (600+)
- Covidien (9,500+)
- DeRoyal (6,000+)
- Dukal (1,300+)
- Ethicon (4,100+)
- GE Healthcare (1,000+)
- Hartmann (600+)
- Hospira (530+)
- ICU Medical (1,700+)
- Masimo (170+)
- Medline (54,000+)
- Midmark (2,500+)
- Roche (300+)
- Smiths Medical (4,000+)
- Sunset Healthcare (450+)
- TrueCare Biomedix (20+)
- View All Brands (5,000+)
Smiths Medical 21-4476-24 - Port-A-Cath Tray, Includes: Single-Lumen Standard Portal, Polysulfone/Titanium, 30.5x14.7x11.4mm, PolyFlow Polyurethane Catheter, 5.8FR
The Smiths Medical 21-4476-24 Port-A-Cath Tray is a professionally configured implantable vascular access tray designed for long-term venous access procedures. This tray includes a single-lumen standard portal made with polysulfone and titanium, measuring 30.5 x 14.7 x 11.4 mm, along with a 5.8FR PolyFlow polyurethane catheter. It is intended to support clinicians during port placement procedures where reliable, repeated vascular access is required.
Built for procedural efficiency and consistent clinical performance, this Port-A-Cath tray provides the essential components needed for implantable port access in oncology, infusion therapy, medication administration, blood sampling, and other vascular access applications. Its compact standard portal design and polyurethane catheter construction support dependable use in appropriate clinical environments.
Key Benefits
- Includes a single-lumen standard portal for controlled vascular access
- Polysulfone and titanium portal construction supports strength and durability
- Compact portal size of 30.5 x 14.7 x 11.4 mm helps support patient comfort after implantation
- 5.8FR PolyFlow polyurethane catheter is designed for reliable fluid pathway performance
- Tray format helps streamline preparation for port placement procedures
- Supports repeated access for infusion therapy, medication delivery, and blood draws
- Suitable for use in hospitals, surgical centers, oncology departments, and specialty vascular access settings
Compatibility and Applications
The Smiths Medical 21-4476-24 Port-A-Cath Tray is intended for use by trained healthcare professionals in procedures requiring an implantable venous access port. Its single-lumen configuration is appropriate for therapies where one dedicated access pathway is required.
Common applications include long-term infusion therapy, chemotherapy support, antibiotic therapy, parenteral nutrition, blood sampling, and other treatments requiring repeated venous access. The 5.8FR polyurethane catheter and standard portal design make this tray suitable for clinical settings where dependable access and procedural consistency are important.
Usage Guidelines
This product should only be used by qualified clinicians trained in implantable vascular access placement and management. Before use, confirm the product size, catheter type, lumen configuration, and tray contents against the procedure requirements and facility protocol.
Maintain sterile technique throughout preparation, placement, access, and dressing procedures. Follow the manufacturers instructions for implantation, catheter trimming if applicable, flushing, locking, and post-placement care. Proper imaging, tip positioning, and patency verification should be completed according to institutional standards and clinical judgment.
Certifications and Safety Standards
The Smiths Medical 21-4476-24 Port-A-Cath Tray should be handled in accordance with applicable healthcare facility policies, sterile procedure standards, and vascular access guidelines. As a medical device used for implantable venous access, it must be stored, inspected, and used according to the manufacturers labeling and all relevant regulatory requirements.
Clinicians should verify packaging integrity, expiration dating, sterility status, and product identification before use. Do not use the tray if the package is opened, damaged, compromised, or if the product appears contaminated.
Comparison with Competitors
Compared with general vascular access trays or non-implantable catheter systems, the Smiths Medical 21-4476-24 Port-A-Cath Tray is designed specifically for long-term implantable port access. Its single-lumen standard portal and polyurethane catheter configuration provide a focused solution for patients who require repeated venous access over an extended period.
The polysulfone and titanium portal design offers a balance of durability, clinical familiarity, and patient-centered sizing. The included 5.8FR catheter supports a streamlined approach for procedures where a smaller catheter profile is clinically appropriate. For facilities comparing implantable port options, this tray offers a practical combination of trusted brand recognition, procedural readiness, and long-term access utility.
Typical User Profile and Application Scenarios
This Port-A-Cath tray is commonly used by vascular access specialists, interventional radiologists, surgeons, oncology teams, infusion therapy clinicians, and hospital-based procedural teams. It is appropriate for healthcare environments that manage patients requiring reliable long-term venous access.
Typical use scenarios include oncology treatment plans, repeated infusion therapy, frequent blood draws, long-term medication administration, and care plans where peripheral venous access may be difficult, unreliable, or clinically unsuitable. The single-lumen format is often selected when one access channel is sufficient for the patients prescribed therapy.
Best Practices for Use and Maintenance
Inspect the tray and all components before opening. Confirm that the product matches the requested device and that the catheter size and portal type are appropriate for the planned procedure. Use aseptic technique during implantation and follow facility policy for skin preparation, sterile field management, and post-procedure documentation.
After implantation, maintain the port according to clinical protocols for flushing, locking, needle access, dressing changes, and infection prevention. Monitor the site for signs of complications such as redness, swelling, pain, leakage, occlusion, or suspected infection. Only trained professionals should access or maintain the port using compatible non-coring needles and approved vascular access supplies.
Regulatory and Safety Information
The Smiths Medical 21-4476-24 Port-A-Cath Tray is intended for professional medical use only. It should be used strictly in accordance with the manufacturers instructions, institutional procedures, and applicable regulations for implantable vascular access devices.
Do not reuse single-use components unless specifically permitted by the manufacturers labeling. Improper use, incorrect placement, inadequate flushing, or failure to maintain sterile technique may increase the risk of infection, thrombosis, occlusion, extravasation, or device-related complications. Final product selection and use should be based on clinician assessment, patient condition, therapy requirements, and facility standards.
How to Order
Select the Smiths Medical 21-4476-24 Port-A-Cath Tray, Includes: Single-Lumen Standard Portal, Polysulfone/Titanium, 30.5x14.7x11.4mm, PolyFlow Polyurethane Catheter, 5.8FR and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.
Smiths Medical #21-4424-24, Port-A-Cath Kit, Includes: Single-Lumen Standard Portal, Titanium, 30.5x14.7x11.4mm, PolyFlow Polyurethane Catheter, 5.8FR, Straight Needle, Blunt Needle, Vein Pick, and Point-Lok Device
$1,052.19 EACH
Smiths Medical #21-4452-24, Port-A-Cath Kit, Includes: Single-Lumen Standard Portal, Polysulfone/Titanium, 28x14.6x11.4mm, PolyFlow Polyurethane Catheter, 5.8FR, Straight Needle, Blunt Needle, Vein Pick, and Point-Lok Device
$972.28 KIT
Smiths Medical #21-4470-24, Port-A-Cath Kit, Includes: Single-Lumen Low Profile Portal, Polysulfone/Titanium, 25x11.5x9.5mm, PolyFlow Polyurethane Catheter, 7.8FR, Straight Needle, Blunt Needle, Vein Pick, and Point-Lok Device
$1,052.17 EACH
Smiths Medical #21-4453-24, Port-A-Cath Tray, Inlcudes: Single-Lumen Standard Portal, Polysulfone/Titanium, 28x14.6x11.4mm, PolyFlow Polyurethane Catheter, 5.8FR, Straight Needle, Blunt Needle, Vein Pick, 18G Introducer Needle, 6FR, J-Guidewire, 90 Needle, Gripper Plus Safety Nee
$1,052.17 TRAY