-
Catheters (6,800+)
- Angiocatheters (50+)
- Closed System Catheters (300+)
- External Catheters (620+)
- Hydrophilic Catheters (140+)
- IV Catheters (1,200+)
- Non-Hydrophilic (20+)
- Plastic Catheters (200+)
- Rubber Catheters (700+)
- Silicone Catheters (770+)
- Ureteral Catheters (100+)
- Urethral Catheters (450+)
- Venous Catheters (240+)
-
Coronavirus (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (20,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Custom Kits
- Dental (14,000+)
- Gloves (8,000+)
-
Gynecology & Urology (1,000+)
- Bed Side Drainage Bags (350+)
- Circumcision (150+)
- Cord Clamps and Clippers (60+)
- Disposable Vaginal Specula (60+)
- Enema Bags (30+)
- External Catheters (620+)
- Foley Catheters and Trays (1,200+)
- Identification (1100+)
- Leg Bag Accessories (10+)
- Leg Bags (280+)
- Reusable Vaginal Specula (900+)
- Specimen Collection (200+)
- Tubing & Connectors (17,000+)
- Urinals / Bed Pans (1,300+)
- Urine Collectors (60+)
- Urological Irrigation Products (10+)
- Vaginal Specula Illumination (2+)
- Systems (11,000+)
- Hygiene (1,000+)
- Incontinence (1,000+)
-
Infection Control (2,500+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Iodine (460+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Infusion All (2,000+)
- IV Bags - Empty (300+)
- IV Bags - Filled (100+)
- Masks (3,800+)
-
Medical Apparel (23,000+)
- Arm Sleeves (240+)
- Beard Covers (20+)
- Bouffant Caps (200+)
- Compression Socks (80+)
- Coveralls (500+)
- Disposables (100+)
- Isolation Gowns (360+)
- Lab Coats (2,200+)
- Lab Jackets (300+)
- Patient Gowns (300+)
- Procedural Gowns (230+)
- Scrubs (20,000+)
- Shoe Covers (270+)
- Surgeon Caps (40+)
- Surgical Gowns (70+)
- Surgical Hoods (20+)
- Surgical Masks (330+)
- Ostomy (400+)
-
PPE (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (23,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Respiratory (500+)
- Sanitizer (600+)
- Surgical Supplies (14,000+)
- Sutures (7,500+)
- Syringes & Needles (14,000+)
-
Wound Care (5,000+)
- ABD Pads (100+)
- Adhesive Bandages (650+)
- Advanced Wound Care (400+)
- Applicators (6,700+)
- Burn care (240+)
- Dressings (7,500+)
- Elastic Bandages (1,600+)
- Gauze (3,300+)
- Ice / Heat Packs (280+)
- Medical Tape (820+)
- Non-Adhering Dressings (100+)
- Ointment & Solutions (450+)
- Self-Adherent Wraps (200+)
- Sponges (2,400+)
- Staple & Suture Removal (1,500+)
- Tegaderm (450+)
- Transparent Dressing (800+)
- Wound Care Prep (120+)
- Wound Cleansers (100+)
- Sales & Deals (100+)
- 3M (4,200+)
- Alaris Medical (600+)
- Amsino International (550+)
- Avanos Medical (40+)
- B Braun (1,500+)
- Baxter (750+)
- BD (2,800+)
- BSN Medical (2,000+)
- Cables & Sensors (3,200+)
- C.R. Bard (4,200+)
- Cardinal Health (6,800+)
- CareFusion (2,100+)
- ConMed (1,500+)
- Cook Medical (600+)
- Covidien (9,500+)
- DeRoyal (6,000+)
- Dukal (1,300+)
- Ethicon (4,100+)
- GE Healthcare (1,000+)
- Hartmann (600+)
- Hospira (530+)
- ICU Medical (1,700+)
- Masimo (170+)
- Medline (54,000+)
- Midmark (2,500+)
- Roche (300+)
- Smiths Medical (4,000+)
- Sunset Healthcare (450+)
- TrueCare Biomedix (20+)
- View All Brands (5,000+)
Smiths Medical 21-4590-24 - KIT PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 1.9MM OD TITANIUM/PLASTIC PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE UNASSEMBLED
The Smiths Medical 21-4590-24 Port-A-Cath Single Lumen Ultra Low Profile Kit is designed for vascular access applications where a compact, low-profile implanted port system is required. This kit features a single lumen titanium and plastic port with a 1 mm inner diameter, 1.9 mm outer diameter, 5.8 Fr catheter size, and 76 cm polyurethane catheter length. The ultra low profile design supports patient comfort while providing dependable access for appropriate infusion therapy, medication delivery, blood sampling, and long-term vascular access needs as directed by a qualified healthcare professional.
The kit includes an unassembled port and catheter configuration with a straight and blunt needle, allowing trained clinicians to prepare and place the system according to facility protocol and clinical requirements. Its combination of titanium, plastic, and polyurethane materials provides a balance of strength, durability, and flexibility for professional healthcare environments.
Key Benefits
- Ultra low profile single lumen port design supports discreet placement and patient comfort.
- 5.8 Fr, 76 cm polyurethane catheter provides flexibility for vascular access procedures.
- Titanium and plastic port construction offers a durable implanted access solution.
- Single lumen configuration is suitable for standard infusion and access applications.
- Unassembled kit format allows clinicians to prepare the device according to procedural needs.
- Designed for use in controlled clinical settings by trained healthcare professionals.
- Supports long-term vascular access when clinically appropriate.
Compatibility and Applications
The Smiths Medical 21-4590-24 Port-A-Cath Single Lumen Ultra Low Profile Kit is intended for use in healthcare settings requiring implanted vascular access. It may be used in applications involving prescribed infusion therapy, medication administration, blood withdrawal, and other access needs determined by the treating clinician.
This port kit is compatible with appropriate Port-A-Cath access procedures and should be used only with compatible access needles, supplies, and clinical techniques approved by the healthcare facility. The 1 mm inner diameter, 1.9 mm outer diameter, and 5.8 Fr catheter profile make it suitable for cases where a compact single lumen access system is preferred.
Usage Guidelines
Use of the Smiths Medical 21-4590-24 Port-A-Cath Kit should be limited to trained clinicians experienced in implanted port placement, vascular access, sterile technique, and device management. Prior to use, verify the product code, kit contents, packaging integrity, expiration date, catheter size, and compatibility with the planned procedure.
The port and catheter should be prepared, assembled, implanted, accessed, flushed, and maintained according to the manufacturer instructions, institutional policies, and applicable clinical standards. Proper aseptic technique should be followed throughout handling and placement. After implantation, ongoing care should include routine assessment of the access site, patency checks, flushing protocols, and monitoring for complications such as infection, occlusion, thrombosis, extravasation, or device malfunction.
Certifications and Safety Standards
The Smiths Medical 21-4590-24 Port-A-Cath Kit is manufactured for professional medical use and should be handled in accordance with applicable healthcare regulations, facility procedures, and manufacturer guidance. Users should confirm product labeling, sterility status, storage requirements, and instructions for use before clinical application.
As with all implanted vascular access devices, safe use depends on proper patient selection, correct placement, sterile handling, validated clinical technique, and consistent post-procedure care. Healthcare providers should follow all relevant infection control, sharps safety, and vascular access standards established by their institution.
Comparison with Competitors
Compared with standard-profile implanted port systems, the Smiths Medical 21-4590-24 Port-A-Cath Kit offers an ultra low profile design that may be preferred where a smaller port profile is clinically appropriate. Its titanium and plastic port construction provides a durable alternative to basic plastic-only configurations, while the polyurethane catheter offers the flexibility commonly required for vascular access procedures.
Compared with dual lumen port systems, this single lumen configuration may be suitable for cases that do not require simultaneous multiple infusion pathways. The unassembled kit format also gives clinicians procedural flexibility, which can be useful in facilities that prefer to assemble components according to established technique and patient-specific placement requirements.
Typical User Profile and Application Scenarios
This product is typically used by interventional radiologists, surgeons, oncology clinicians, infusion teams, vascular access specialists, and trained hospital staff involved in the placement and management of implanted port systems. It is suitable for acute care hospitals, outpatient infusion centers, oncology departments, ambulatory surgery centers, and specialty clinics that provide long-term vascular access services.
Typical application scenarios may include patients requiring repeated vascular access for prescribed therapies, long-term infusion regimens, blood draws, or other clinician-directed access needs. Final device selection should be based on patient anatomy, therapy requirements, anticipated duration of access, provider judgment, and facility protocol.
Best Practices for Use and Maintenance
Before use, inspect the packaging and device components carefully and confirm that the correct kit has been selected. Maintain sterile technique during preparation and placement, and follow the manufacturer instructions for assembly and implantation. Use only compatible access devices and follow institutional policies for flushing, locking, dressing, and site care.
After implantation, monitor the port site regularly for redness, swelling, tenderness, drainage, pain, difficulty flushing, resistance, or any sign of infection or device-related complication. Document access, flushing, medication administration, blood withdrawal, maintenance procedures, and any clinical concerns according to facility standards. Replace or manage accessories as required by protocol and never use excessive force when accessing, flushing, or withdrawing from the device.
Regulatory and Safety Information
The Smiths Medical 21-4590-24 Port-A-Cath Kit is a medical device intended for use by qualified healthcare professionals. It should be stored, handled, implanted, accessed, and maintained only according to the manufacturer instructions for use, product labeling, and applicable clinical guidelines. Do not use the product if packaging is damaged, sterility is compromised, or the device appears defective.
Clinical teams should assess patient suitability before use and remain alert for known risks associated with implanted vascular access devices, including infection, catheter occlusion, thrombosis, catheter fracture, migration, embolization, extravasation, and access complications. Proper training, sterile technique, and routine maintenance are essential for safe and effective device performance.
How to Order
Select the Smiths Medical 21-4590-24 KIT PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 1.9MM OD TITANIUM/PLASTIC PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE UNASSEMBLED and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.
Smiths Medical #21-4590-24, KIT PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 1.9MM OD TITANIUM/PLASTIC PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE UNASSEMBLED
$783.36 EACH
Smiths Medical #21-4052-24, KIT PORT-A-CATH SINGLE LUMEN 1MM ID 1.9MM OD POLYSULFONE/TITANIUM PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE UNASSEMBLED
$402.54 EACH
Smiths Medical #21-4572-24, KIT PORT-A-CATH SINGLE LUMEN ULTRA LOW PROFILE 1MM ID 1.9MM OD TITANIUM PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE UNASSEMBLED
$560.63 EACH
Smiths Medical #21-4182-24, KIT PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 1.9MM OD PLASTIC PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK UNASSEMBLED
$402.54 EACH