Smiths Medical 21-7345-24 - CADD High Volume Administration Set, Includes: Bag Spike, Flow Stop, 0.2 Micron Air-Eliminating Filter, Clamp, Injection Site, One-Way Checkvale with Male Luer, 120" Length, 20 ml PV, Not Made with DEHP, 15/bx

CADD High Volume Administration Set, Includes: Bag Spike, Flow Stop, 0.2 Micron Air-Eliminating Filter, Clamp, Injection Site, One-Way Checkvale with Male Luer, 120
Part Number Smiths Medical 21-7345-24
SKU Number CIA8066897
Sell Unit BOX
Ships Within Special Order
List Price $359.54
Enter a valid quantity
Product Description

Smiths Medical 21-7345-24 - CADD High Volume Administration Set, Includes: Bag Spike, Flow Stop, 0.2 Micron Air-Eliminating Filter, Clamp, Injection Site, One-Way Checkvale with Male Luer, 120" Length, 20 ml PV, Not Made with DEHP, 15/bx

The Smiths Medical 21-7345-24 CADD High Volume Administration Set is designed for controlled fluid delivery when used with compatible CADD infusion systems. This high volume administration set includes a bag spike, Flow Stop feature, 0.2 micron air-eliminating filter, clamp, injection site, one-way checkvalve with male luer, 120 inch tubing length, and a 20 mL priming volume. Supplied 15 per box, it supports clinical environments that require dependable infusion setup, consistent flow management, and patient-focused safety features.

This set is not made with DEHP, making it suitable for healthcare facilities that prefer DEHP-free administration components where clinically appropriate. Its longer 120 inch tubing provides additional reach for bedside, ambulatory, outpatient, and specialty infusion applications.

Key Benefits

  • Designed for high volume administration with compatible CADD infusion pumps.
  • Includes a 0.2 micron air-eliminating filter to support filtered fluid delivery.
  • Flow Stop feature helps reduce the risk of unintended free flow during setup and handling.
  • 120 inch tubing length provides extended reach for flexible patient positioning.
  • One-way checkvalve with male luer supports directional flow control and secure connection.
  • Integrated clamp allows manual flow interruption when required by facility protocol.
  • Injection site supports medication access according to clinical procedures.
  • Not made with DEHP for facilities seeking DEHP-free administration set options.
  • Packaged 15 per box for convenient clinical inventory management.

Compatibility and Applications

The Smiths Medical 21-7345-24 CADD High Volume Administration Set is intended for use with compatible CADD infusion pump systems and related infusion therapy protocols. It may be used in hospital departments, outpatient infusion centers, home infusion programs, specialty pharmacy services, and other healthcare settings where CADD-compatible high volume administration sets are required.

Common applications may include controlled infusion therapy, high volume medication delivery, filtered administration requirements, and infusion workflows that require long tubing length, flow control, and secure luer connection. Always confirm pump compatibility, medication suitability, and facility protocol before use.

Usage Guidelines

Use the administration set only as directed by the device manufacturer, prescribing clinician, and facility procedure. Inspect the package before opening and do not use if the packaging is damaged, opened, or compromised. Prime the set carefully according to the pump instructions and ensure the 0.2 micron air-eliminating filter, clamp, injection site, checkvalve, and male luer connection are properly positioned before starting therapy.

Healthcare professionals should verify the correct therapy order, medication, dose, route, rate, priming volume, and pump programming before use. The set should be connected using aseptic technique and monitored throughout therapy according to clinical standards and institutional policy.

Certifications and Safety Standards

The Smiths Medical 21-7345-24 CADD High Volume Administration Set is manufactured for use in regulated healthcare environments and should be handled in accordance with applicable clinical, infection control, and infusion therapy standards. The product is not made with DEHP, supporting facilities that require or prefer administration products without DEHP in the fluid pathway where appropriate.

Users should refer to the product packaging, manufacturer documentation, and facility policy for complete information regarding sterility, storage requirements, single-use guidance, disposal, and safety precautions.

Comparison with Competitors

Compared with general IV administration tubing, the Smiths Medical 21-7345-24 is designed specifically for CADD-compatible infusion workflows and includes multiple integrated features that support controlled administration. The combination of a bag spike, Flow Stop, 0.2 micron air-eliminating filter, injection site, clamp, one-way checkvalve with male luer, and extended 120 inch tubing provides a more complete setup for high volume CADD infusion applications.

For facilities already using CADD pump systems, this administration set offers the benefit of system-specific compatibility and workflow consistency. Its 20 mL priming volume and 15 per box packaging also support predictable inventory planning and standardized clinical use.

Typical User Profile and Application Scenarios

This administration set is commonly used by nurses, infusion specialists, pharmacists, home infusion clinicians, oncology teams, pain management teams, and other trained healthcare professionals who manage CADD-compatible infusion therapy. It is suitable for clinical situations where high volume administration, filtered delivery, longer tubing reach, and controlled flow management are important.

Typical scenarios include outpatient infusion therapy, bedside infusion management, home infusion setup, ambulatory pump use, and specialty medication administration where the prescribed therapy requires a compatible CADD high volume administration set with a 0.2 micron air-eliminating filter.

Best Practices for Use and Maintenance

Store the product in a clean, dry area according to the manufacturers storage recommendations. Before use, confirm the correct product code, tubing length, filter type, priming volume, and box quantity against the clinical order or supply requirement. Maintain aseptic technique during preparation and connection to reduce contamination risk.

Do not reuse single-use administration sets. Replace the set according to manufacturer guidance, medication requirements, and facility protocol. After use, dispose of the set in accordance with institutional policy and applicable medical waste regulations.

Regulatory and Safety Information

The Smiths Medical 21-7345-24 CADD High Volume Administration Set should be used only by trained healthcare professionals or properly instructed caregivers under clinical supervision. It is important to verify compatibility with the intended CADD pump system before use. Incorrect product selection, improper priming, loose connections, or incorrect pump programming may affect therapy delivery.

Follow all applicable warnings, precautions, and instructions provided by the manufacturer. This product should not be used if the package integrity is compromised or if any component appears damaged. For patient safety, monitor the infusion site, tubing, filter, pump status, and therapy response according to the prescribed care plan.

How to Order

Select the Smiths Medical 21-7345-24 CADD High Volume Administration Set, Includes: Bag Spike, Flow Stop, 0.2 Micron Air-Eliminating Filter, Clamp, Injection Site, One-Way Checkvale with Male Luer, 120" Length, 20 ml PV, Not Made with DEHP, 15/bx, and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products