Smiths Medical 3500-VER6 - Medfusion 3500 (Ver. 6) Pump, Refurbished, Each

Smiths Medical # 3500-VER6 - Medfusion 3500 (Ver. 6) Pump, Refurbished, Each
Part Number Smiths Medical 3500-VER6
SKU Number CIA8031966
Sell Unit EACH
Ships Within Call for Availability
List Price $2,333.50
Product Description

Smiths Medical 3500-VER6 - Medfusion 3500 (Ver. 6) Pump, Refurbished, Each

The Smiths Medical 3500-VER6 Medfusion 3500 Version 6 Pump is a refurbished syringe infusion pump designed for the controlled delivery of medications and fluids from compatible syringes. Developed for clinical environments that require carefully regulated infusion rates, the Medfusion 3500 supports a broad range of therapies across neonatal, pediatric, adult, critical care, anesthesia, and specialty infusion settings.

Version 6 software provides structured programming options, configurable clinical profiles, dose calculation capabilities, and safety-oriented monitoring features. Each refurbished pump should be inspected, tested, and prepared for service according to the refurbisher's quality procedures before being placed into clinical use.

Key Benefits

  • Supports precise delivery of medications and fluids at controlled infusion rates
  • Designed for neonatal, pediatric, adult, and critical care applications
  • Accommodates multiple compatible syringe brands and syringe sizes
  • Provides programmable dose, volume, time, and delivery-rate options
  • Offers pressure monitoring and configurable alarm functions
  • Includes medication safety features supported by Version 6 software
  • Compact design helps conserve space around bedsides and treatment areas
  • Refurbished configuration may provide a cost-effective alternative to purchasing new equipment

Compatibility and Applications

The Medfusion 3500 Version 6 Pump is intended for use with approved syringe brands and sizes identified in the applicable operator's manual and the facility's validated pump configuration. Compatible selections may include commonly used syringes ranging from small-volume syringes to larger syringe formats, depending on the installed configuration.

The pump may be used for arterial, enteral, epidural, intravenous, spinal, and subcutaneous delivery when the selected therapy, medication, administration set, and access route are clinically appropriate. Typical applications include continuous infusions, intermittent therapies, loading doses, bolus delivery, weight-based dosing, and other carefully controlled medication-delivery protocols.

Compatibility must be confirmed before use. Clinicians should verify the syringe manufacturer, syringe size, concentration, programmed dose, delivery route, and installed drug-library settings for every infusion.

Usage Guidelines

Only qualified healthcare professionals who have completed facility-approved training should operate the Smiths Medical Medfusion 3500 Pump. Before starting an infusion, inspect the pump, power cord, battery status, mounting hardware, syringe-retention components, display, keypad, and alarm system for damage or abnormal operation.

  1. Confirm that the pump has passed the facility's required inspection and preventive maintenance procedures.
  2. Select a compatible syringe and prepare the medication using approved aseptic techniques.
  3. Load the syringe according to the Version 6 operator's manual, ensuring that the barrel flange and plunger are securely positioned.
  4. Confirm the syringe brand and size displayed by the pump before accepting the selection.
  5. Program the prescribed concentration, dose, rate, volume, and applicable limits.
  6. Independently verify all settings when required by institutional policy.
  7. Connect the administration tubing, assess the access site, and begin the infusion.
  8. Monitor the patient, infusion pathway, syringe volume, pump display, and alarm status throughout therapy.

Certifications and Safety Standards

The Medfusion 3500 was originally manufactured as a medical syringe infusion pump for use under applicable healthcare equipment requirements. The regulatory status, electrical safety certification, labeling, and service documentation for a refurbished unit may depend on its serial number, manufacturing history, software revision, refurbishment process, and intended market.

Purchasers should request documentation confirming the unit's operational testing, electrical safety inspection, preventive maintenance status, software version, battery condition, and refurbishment warranty. Clinical facilities should evaluate the device under their biomedical engineering, infection prevention, risk management, and medical equipment policies before use.

Comparison with Competitors

Compared with basic syringe drivers, the Medfusion 3500 Version 6 provides more comprehensive programming options, configurable clinical workflows, multiple syringe selections, and medication safety functions suitable for hospital-based infusion therapy. Its established use in neonatal and pediatric care makes it particularly relevant where small-volume medication delivery and carefully controlled rates are essential.

Newer syringe pump platforms may offer updated interfaces, expanded wireless connectivity, centralized reporting, and more advanced interoperability. However, a properly serviced Medfusion 3500 Version 6 may remain a practical option for facilities that already maintain compatible devices, accessories, training programs, and biomedical support resources.

Typical User Profile and Application Scenarios

This refurbished syringe infusion pump is suited to hospitals, outpatient treatment centers, specialty clinics, surgical facilities, infusion departments, and other qualified healthcare organizations. Typical users include registered nurses, anesthesia professionals, physicians, pharmacists, clinical educators, biomedical technicians, and other trained personnel responsible for medication administration or device management.

Common application scenarios include neonatal and pediatric intensive care, adult critical care, anesthesia, emergency care, controlled medication infusions, specialty drug administration, and therapies requiring precise delivery from a syringe. The pump should only be used when its configuration, performance specifications, and clinical capabilities meet the requirements of the intended procedure.

Best Practices for Use and Maintenance

  • Verify the selected syringe brand and size before every infusion
  • Use only compatible syringes and administration components
  • Check medication concentration, patient weight, dose, rate, and volume before starting therapy
  • Use independent double-check procedures for high-alert medications when required
  • Keep the pump connected to approved AC power when practical and monitor battery condition
  • Respond promptly to occlusion, syringe, battery, system, and end-of-infusion alarms
  • Clean and disinfect the exterior using approved products and procedures
  • Do not immerse the pump or allow cleaning fluid to enter openings or electrical connections
  • Maintain documented preventive maintenance, calibration, inspection, and repair records
  • Remove the pump from service immediately if damage, inaccurate delivery, repeated alarms, or abnormal operation is suspected

Regulatory and Safety Information

The Smiths Medical 3500-VER6 Medfusion 3500 is a prescription medical device intended for operation by trained healthcare professionals. It should not be used without the applicable Version 6 operator's manual, facility-approved clinical protocols, and confirmation that the device has passed all required inspections.

Medical device corrections and safety communications have been issued for certain Medfusion 3500 pumps and software configurations. Before purchasing or deploying a refurbished unit, confirm its exact software revision, serial number, correction status, service history, and eligibility for clinical use. Version 6 designation alone should not replace serial-number-specific verification or current regulatory review.

The receiving facility is responsible for confirming that the pump complies with applicable local regulations and institutional requirements. Medication delivery must be monitored clinically, and the pump should never be treated as a substitute for professional judgment, patient observation, or established infusion safety procedures.

How to Order

Select the Smiths Medical 3500-VER6 Medfusion 3500 (Ver. 6) Pump, Refurbished, Each and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.