Smiths Medical 370901 - ABC ST E144 2FL 10/CA

ABC ST E144 2FL 10/CA
Part Number Smiths Medical 370901
SKU Number CIA1073312
Sell Unit CASE
Ships Within Special Order
List Price $69.92
Enter a valid quantity
Product Description

Smiths Medical 370901 - ABC ST E144 2FL 10/CA

The Smiths Medical 370901 ABC ST E144 2FL 10/CA is an adult MRI-length dual-limb anesthesia breathing circuit designed for dependable respiratory gas delivery and return during anesthesia and other compatible breathing system applications. The circuit features two 144-inch breathing limbs, providing approximately 366 cm of extended tubing length for environments where additional distance between the patient and anesthesia equipment is required.

This configuration includes a gas sampling port elbow, a straight wye connection, and two breathing filters. The extended-length design is particularly suitable for MRI and other procedural settings where equipment placement may require greater separation from the patient. Each case contains 10 breathing circuit units for efficient clinical inventory management.

Key Benefits

  • Adult dual-limb breathing circuit configuration supports separate inspiratory and expiratory gas pathways.
  • Two 144-inch breathing limbs provide extended reach for MRI and specialized procedural environments.
  • Gas sampling port supports connection to compatible gas monitoring equipment.
  • Straight wye configuration provides a practical patient-side connection arrangement.
  • Includes two breathing filters for a complete procedural configuration based on the specified product setup.
  • Extended tubing length helps accommodate anesthesia equipment positioned away from the patient.
  • Packaged 10 units per case to support hospital, surgical, and anesthesia department inventory requirements.

Compatibility and Applications

The Smiths Medical 370901 breathing circuit is intended for use with compatible anesthesia machines, breathing systems, gas monitoring equipment, and patient airway connections that meet the required connector specifications. Its extended MRI-length configuration is designed for clinical environments where the anesthesia delivery system may need to remain at a greater distance from the patient.

Typical applications may include MRI procedures requiring anesthesia support, operating rooms, procedural suites, diagnostic imaging departments, and other monitored care environments. Compatibility with the specific anesthesia machine, airway device, monitoring system, and clinical protocol should always be confirmed before use.

Usage Guidelines

Before use, inspect the packaging and all circuit components for damage, contamination, loose connections, or other visible defects. Assemble the circuit according to the applicable manufacturer instructions and facility protocol. Confirm that the inspiratory and expiratory limbs are connected correctly and that the patient-side wye, gas sampling connection, and breathing filters are securely positioned.

Perform all required pre-use system checks, including leak testing and verification of gas flow, before connecting the circuit to a patient. The gas sampling port should only be connected to compatible monitoring equipment using the appropriate sampling setup. During use, monitor the circuit for disconnection, obstruction, kinking, excessive condensation, or other conditions that could affect respiratory performance.

Certifications and Safety Standards

Smiths Medical respiratory and anesthesia products are manufactured for professional healthcare applications and should be used in accordance with the labeling, instructions for use, applicable regulatory requirements, and institutional safety procedures supplied for the specific product. Healthcare facilities should verify current product documentation, regulatory status, lot information, and any required certifications before clinical use.

Only trained healthcare professionals familiar with anesthesia breathing systems, respiratory monitoring, and the connected equipment should set up and use this product.

Comparison with Competitors

Compared with standard-length adult anesthesia circuits, the Smiths Medical 370901 provides a substantially extended 144-inch dual-limb configuration that can be advantageous in MRI and specialized procedural environments. The inclusion of two breathing filters, a gas sampling port elbow, and a straight wye provides a defined configuration that may reduce the need to source certain components separately.

When comparing this circuit with alternatives from other manufacturers, purchasing teams should evaluate tubing length, dual-limb configuration, included filtration components, gas sampling capability, connector compatibility, packaging quantity, and suitability for the intended clinical environment. Product selection should be based on equipment compatibility and facility-approved clinical protocols rather than tubing length alone.

Typical User Profile and Application Scenarios

The Smiths Medical 370901 is primarily intended for hospitals, surgical centers, anesthesia departments, diagnostic imaging facilities, and other healthcare organizations that require extended-length adult breathing circuits. Typical users include anesthesiologists, certified registered nurse anesthetists, anesthesia technicians, respiratory therapists, and other appropriately trained clinical personnel.

A common application scenario involves an adult patient receiving anesthesia or respiratory support during an MRI procedure where the anesthesia machine or associated equipment must be positioned at a greater distance from the patient. The 144-inch dual-limb tubing provides the extended reach needed for this type of equipment arrangement while maintaining separate inspiratory and expiratory pathways.

Best Practices for Use and Maintenance

  • Verify the product code and configuration before opening the package.
  • Inspect all tubing, connectors, filters, and ports before patient use.
  • Confirm secure connections throughout the breathing system before beginning a procedure.
  • Perform the anesthesia machine and breathing circuit checks required by the equipment manufacturer and facility protocol.
  • Route the extended tubing carefully to minimize kinking, compression, pulling, and accidental disconnection.
  • Monitor for condensation and manage accumulated moisture according to established clinical procedures.
  • Do not use a product with damaged packaging or components.
  • Follow the manufacturer instructions and facility policy regarding use, replacement, handling, and disposal.

Regulatory and Safety Information

The Smiths Medical 370901 is a professional medical breathing circuit intended for use by trained healthcare personnel. It should only be used for its labeled purpose and with compatible equipment. Users must review the current manufacturer instructions, product labeling, warnings, precautions, and institutional procedures before use.

Proper circuit assembly and pre-use testing are essential. Incorrect connections, leaks, obstructions, kinks, disconnected components, or incompatible accessories may interfere with ventilation or gas delivery. During clinical use, the patient and breathing system should be continuously monitored according to applicable standards of care and facility protocols. Store the product under the conditions specified on the manufacturer packaging and follow appropriate procedures for handling and disposal.

How to Order

Select the Smiths Medical 370901 ABC ST E144 2FL 10/CA and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.