Smiths Medical 372036 - CIRCUIT ANESTHESIA PEDIATRIC 50.8MMDIA 40INL DUAL-LIMB GAS SAMPLING PORT ELBOW STRAIGHT WYE BACTERIAL/VIRAL FILTERX2 1L BAG PORTEX LATEX DISPOSABLE (20/CS)

Smiths Medical # 372036 - CIRCUIT ANESTHESIA PEDIATRIC 50.8MMDIA 40INL DUAL-LIMB GAS SAMPLING PORT ELBOW STRAIGHT WYE BACTERIAL/VIRAL FILTERX2 1L BAG PORTEX LATEX DISPOSABLE (20/CS)
Part Number Smiths Medical 372036
SKU Number CIA2543927
Sell Unit CASE
Ships Within Special Order
List Price $117.28
Enter a valid quantity
Product Description

Smiths Medical 372036 - CIRCUIT ANESTHESIA PEDIATRIC 50.8MMDIA 40INL DUAL-LIMB GAS SAMPLING PORT ELBOW STRAIGHT WYE BACTERIAL/VIRAL FILTERX2 1L BAG PORTEX LATEX DISPOSABLE (20/CS)

The Smiths Medical 372036 pediatric anesthesia circuit is a disposable, dual-limb breathing circuit designed to support controlled delivery and removal of respiratory gases during pediatric anesthesia procedures. The circuit features a 50.8 mm diameter configuration, a 40-inch length, a gas sampling port elbow, a straight wye connector, two bacterial and viral filters, and a 1-liter breathing bag.

This Portex latex anesthesia circuit provides a complete respiratory pathway for use with compatible anesthesia machines and pediatric patient connections. Its integrated components help streamline operating room preparation by reducing the need to assemble multiple separate accessories. Each case contains 20 disposable circuits for efficient inventory management in hospitals, surgical centers, and anesthesia departments.

Key Benefits

  • Pediatric configuration designed for anesthesia and respiratory gas management
  • Dual-limb design separates inspiratory and expiratory gas pathways
  • 40-inch circuit length supports practical equipment positioning around the patient
  • Gas sampling port elbow allows connection to compatible gas monitoring equipment
  • Straight wye connector supports an organized connection between the circuit and patient interface
  • Includes two bacterial and viral filters for added filtration within the breathing system
  • Supplied with a 1-liter breathing bag appropriate for pediatric anesthesia applications
  • Disposable construction supports infection-control protocols and efficient turnover between procedures
  • Complete circuit configuration may reduce preparation time and the number of separately sourced components
  • Packaged 20 circuits per case for high-volume clinical environments

Compatibility and Applications

The Smiths Medical 372036 circuit is intended for use in pediatric anesthesia procedures where a dual-limb breathing system is required. It may be used in operating rooms, pediatric surgical units, ambulatory surgery centers, specialty procedure rooms, and other controlled clinical environments.

The circuit is designed to connect with compatible anesthesia machines, respiratory gas monitoring equipment, and appropriate pediatric patient interfaces. The gas sampling port elbow supports connection to compatible monitoring lines used to assess respiratory gases during a procedure. The straight wye provides a central connection point between the inspiratory limb, expiratory limb, and patient-side components.

Compatibility should always be confirmed with the anesthesia machine, airway device, monitoring system, and other accessories selected for the procedure. Clinicians should verify connector dimensions, circuit configuration, filtration requirements, and patient suitability before use.

Usage Guidelines

Before opening the package, inspect it for punctures, tears, moisture, or other evidence of damage. Do not use the circuit if the packaging is compromised or if any component appears damaged, contaminated, loose, or incomplete.

Remove the circuit using aseptic handling practices and connect the inspiratory and expiratory limbs to the appropriate ports on the compatible anesthesia machine. Attach the gas sampling line to the designated sampling port when gas monitoring is required. Confirm that both bacterial and viral filters, the straight wye, elbow, and 1-liter bag are securely positioned.

Perform the anesthesia machine and breathing circuit checks required by the healthcare facility before connecting the circuit to the patient. Check for leaks, obstructions, incorrect connections, excessive resistance, damaged tubing, and proper gas flow. Monitor the patient and the performance of the breathing system continuously throughout the procedure.

This product is disposable and should be used in accordance with the manufacturer's instructions, institutional protocols, and applicable infection-control procedures. Do not reuse, reprocess, or resterilize unless the official product labeling specifically permits such action.

Certifications and Safety Standards

The Smiths Medical 372036 pediatric anesthesia circuit should be handled and used in accordance with the manufacturer's current product labeling, applicable medical device requirements, and the healthcare facility's anesthesia and infection-control policies.

Clinical staff should review the product packaging and instructions for use for applicable regulatory status, storage conditions, material information, warnings, precautions, and approved indications. Only trained healthcare professionals familiar with pediatric anesthesia breathing systems should assemble, test, and use this product.

The circuit must be checked before every procedure to confirm secure connections, proper airflow, system integrity, and compatibility with the selected anesthesia equipment. Appropriate patient monitoring should remain in place throughout use.

Comparison with Competitors

Compared with basic pediatric breathing circuits that require filters, sampling components, and breathing bags to be sourced separately, the Smiths Medical 372036 provides a coordinated disposable setup that includes two bacterial and viral filters, a gas sampling port elbow, a straight wye, and a 1-liter bag.

The dual-limb configuration provides separate pathways for inspiratory and expiratory gases, while the 40-inch length offers a compact setup for pediatric anesthesia environments. The inclusion of two filters may also help facilities standardize breathing circuit preparation when dual filtration is part of the clinical protocol.

Product selection should be based on the patient's needs, anesthesia machine compatibility, required circuit length, filtration strategy, connector configuration, material preferences, and institutional purchasing standards. Competing products may differ in tubing length, filter type, bag capacity, gas sampling arrangement, packaging quantity, and material composition.

Typical User Profile and Application Scenarios

The Smiths Medical 372036 anesthesia circuit is intended for anesthesiologists, certified registered nurse anesthetists, anesthesia assistants, respiratory therapists, operating room nurses, surgical technologists, and other trained clinical personnel involved in pediatric perioperative care.

Typical applications include planned pediatric surgical procedures, outpatient procedures requiring general anesthesia, diagnostic procedures performed under anesthesia, and other clinical situations where a disposable dual-limb pediatric breathing circuit is selected.

Materials management teams and clinical purchasing departments may also choose this product when standardizing pediatric anesthesia supplies across operating rooms or procedure areas. The 20-per-case packaging is suitable for facilities that need dependable access to individually packaged disposable circuits.

Best Practices for Use and Maintenance

  • Store unopened circuits in a clean, dry area within the temperature and environmental limits stated on the packaging
  • Rotate inventory by expiration date and inspect packaging before distribution to clinical areas
  • Confirm that the circuit configuration matches the pediatric procedure and anesthesia machine setup
  • Secure every connection before performing the required leak and flow tests
  • Verify that the gas sampling port is connected correctly or safely capped when not in use
  • Inspect both filters for damage, blockage, moisture accumulation, or incorrect placement
  • Avoid twisting, stretching, crushing, or sharply bending the breathing limbs
  • Position the circuit to reduce unnecessary tension on the patient's airway device
  • Monitor airway pressure, ventilation parameters, gas values, and circuit performance throughout the procedure
  • Replace the circuit immediately if contamination, damage, obstruction, leakage, or performance concerns are identified
  • Dispose of the used circuit according to facility policy and applicable regulations for contaminated medical waste

Regulatory and Safety Information

This anesthesia circuit is intended for professional clinical use and should only be used by qualified personnel trained in pediatric anesthesia equipment and breathing system management. It is not intended for unsupervised home use.

The product contains latex and should not be used when the patient or clinical team requires a latex-free breathing circuit. Review the official product labeling for complete material information and latex-related warnings before use.

Do not use the circuit if the package has been opened, damaged, or contaminated. Do not substitute components, alter the circuit, or connect it to incompatible equipment. Incorrect assembly, obstructed tubing, unsecured connections, filter blockage, or failure to perform pre-use checks may interfere with ventilation and gas delivery.

Always follow the manufacturer's instructions for use, the anesthesia machine manufacturer's recommendations, institutional policies, and applicable regulatory requirements. Product specifications and packaging may be updated, so purchasers should confirm current information before ordering or clinical use.

How to Order

Select the Smiths Medical 372036 CIRCUIT ANESTHESIA PEDIATRIC 50.8MMDIA 40INL DUAL-LIMB GAS SAMPLING PORT ELBOW STRAIGHT WYE BACTERIAL/VIRAL FILTERX2 1L BAG PORTEX LATEX DISPOSABLE (20/CS) and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

```