(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 384006 - CIRCUIT ANESTHESIA ADULT 25.4MMDIA 40INL SINGLE-LIMB GAS SAMPLING ELBOW/GAS SAMPLING PORT ELBOW FILTER 3L BAG MASK LARGE ADULT 10FTL MALE/MALE GAS SAMPLING LINE PORTEX LATEX DISPOSABLE (20/CS)

Smiths Medical # 384006 - CIRCUIT ANESTHESIA ADULT 25.4MMDIA 40INL SINGLE-LIMB GAS SAMPLING ELBOW/GAS SAMPLING PORT ELBOW FILTER 3L BAG MASK LARGE ADULT 10FTL MALE/MALE GAS SAMPLING LINE PORTEX LATEX DISPOSABLE (20/CS)
Part Number Smiths Medical 384006
SKU Number CIA1073334
Sell Unit CASE
Ships Within Special Order
List Price Call for Pricing
Product Description

Smiths Medical 384006 - CIRCUIT ANESTHESIA ADULT 25.4MMDIA 40INL SINGLE-LIMB GAS SAMPLING ELBOW/GAS SAMPLING PORT ELBOW FILTER 3L BAG MASK LARGE ADULT 10FTL MALE/MALE GAS SAMPLING LINE PORTEX LATEX DISPOSABLE (20/CS)

The Smiths Medical 384006 anesthesia circuit is a disposable adult single-limb breathing circuit designed for use during anesthesia delivery, respiratory gas sampling, and supported ventilation. The circuit features a 25.4 mm diameter and a 40-inch length, providing a compact configuration for connecting an adult patient to compatible anesthesia and respiratory equipment.

This complete anesthesia circuit includes a gas sampling elbow, gas sampling port elbow, respiratory filter, 3-liter breathing bag, large adult mask, and a 10-foot male-to-male gas sampling line. By combining essential breathing and monitoring components in one procedural setup, the Smiths Medical 384006 helps clinical teams prepare anesthesia workstations efficiently and maintain a consistent equipment configuration.

The circuit is manufactured for single-patient use and is supplied as 20 disposable anesthesia circuits per case.

Key Benefits

  • Adult single-limb anesthesia circuit designed for controlled delivery of anesthetic and respiratory gases
  • 25.4 mm circuit diameter supports an appropriate breathing pathway for adult anesthesia applications
  • 40-inch circuit length provides practical positioning while helping limit unnecessary tubing around the procedure area
  • Gas sampling elbow and gas sampling port elbow support respiratory gas monitoring when connected to compatible equipment
  • Included filter supports respiratory hygiene within the breathing circuit
  • Three-liter breathing bag supports manual ventilation and visual observation of breathing activity
  • Large adult mask is suitable for patients requiring a larger facial mask size
  • Ten-foot male-to-male gas sampling line provides extended reach between the breathing circuit and compatible gas monitoring equipment
  • Complete component configuration reduces the need to obtain multiple accessories separately
  • Disposable construction helps streamline room turnover and eliminates routine circuit reprocessing
  • Packaged 20 circuits per case to support inventory planning in high-volume clinical facilities

Compatibility and Applications

The Smiths Medical 384006 adult anesthesia circuit is intended for connection to compatible anesthesia machines, respiratory gas delivery systems, patient monitoring equipment, and accessories that accept the supplied circuit and sampling-line connections. Compatibility should always be verified before clinical use because connection requirements can vary between anesthesia workstations and monitoring systems.

Typical applications include general anesthesia, monitored surgical procedures, outpatient interventions, diagnostic procedures requiring anesthesia support, and other controlled clinical situations where respiratory gases must be delivered and sampled. The circuit may be used in operating rooms, ambulatory surgery centers, hospital procedure departments, and appropriately equipped specialty clinics.

The included large adult mask may be appropriate for adult patients whose facial dimensions require a larger mask. Clinicians should select mask size according to the individual patient and confirm that an effective seal can be maintained.

Usage Guidelines

  1. Inspect the outer packaging before use and do not use the circuit if the package is damaged, opened, wet, or otherwise compromised.
  2. Confirm that the product number, circuit dimensions, mask size, breathing bag capacity, and included accessories match the planned procedure.
  3. Remove the circuit using appropriate infection-control practices and inspect all tubing, connectors, elbows, the filter, mask, breathing bag, and gas sampling line.
  4. Connect the single-limb circuit to the compatible anesthesia or respiratory system according to the equipment manufacturers instructions.
  5. Attach the 3-liter breathing bag, large adult mask, filter, sampling elbows, and gas sampling line as required by the clinical setup.
  6. Perform the anesthesia machine and breathing-system pre-use tests required by the healthcare facility, including leak, flow, pressure, obstruction, and connection checks.
  7. Verify that the gas sampling line is securely connected and that the monitoring system is receiving appropriate respiratory gas data.
  8. Position the circuit to minimize pulling, twisting, compression, accidental disconnection, and excessive pressure on the patient connection.
  9. Monitor ventilation, airway pressure, respiratory gas values, breathing bag movement, and circuit integrity throughout the procedure.
  10. Dispose of the complete circuit after use according to facility procedures and applicable regulations for contaminated clinical waste.

Certifications and Safety Standards

The Smiths Medical 384006 should be used in accordance with the manufacturers current labeling, instructions for use, applicable regulatory requirements, and the healthcare facilitys anesthesia and infection-control policies. Before purchasing or placing the product into service, healthcare organizations should review the current package documentation for applicable regulatory status, manufacturing standards, storage requirements, and safety information.

Clinical users should follow recognized standards for anesthesia equipment inspection, breathing-system testing, patient monitoring, infection prevention, and medical waste disposal. Product documentation and lot information should be retained when required by institutional purchasing, inventory-control, or quality-assurance procedures.

Comparison with Competitors

Compared with basic anesthesia circuits supplied without procedural accessories, the Smiths Medical 384006 provides a more complete adult breathing system that includes a filter, 3-liter breathing bag, large adult mask, gas sampling elbows, and a 10-foot gas sampling line. This consolidated configuration can reduce the time required to identify and assemble separate components before a procedure.

The 40-inch circuit provides a more compact setup than longer adult anesthesia circuits. This may help reduce excess tubing near the anesthesia workstation, although the available distance between the patient and equipment should be evaluated before use. The included large adult mask also differentiates this configuration from similar circuit packages supplied with small or medium adult masks.

Facilities comparing this product with alternatives should consider circuit length, diameter, mask size, bag capacity, filter requirements, sampling-line connections, anesthesia machine compatibility, packaging quantity, latex information, and established clinical protocols rather than selecting a circuit based only on price.

Typical User Profile and Application Scenarios

The Smiths Medical 384006 is intended for trained healthcare professionals responsible for anesthesia delivery and respiratory monitoring. Typical users include anesthesiologists, certified registered nurse anesthetists, anesthesia assistants, operating room nurses, respiratory therapists, surgical technologists, and clinical personnel working under approved institutional protocols.

A typical application involves preparing an adult anesthesia workstation for a surgical procedure. The clinician connects the 40-inch single-limb breathing circuit to the anesthesia system, installs the supplied filter and 3-liter breathing bag, selects the included large adult mask when appropriate, and connects the gas sampling line to a compatible respiratory gas monitor. The complete system is tested before patient connection and monitored continuously during use.

The case quantity of 20 circuits is well suited to hospitals, ambulatory surgery centers, procedural departments, and other facilities that maintain standardized disposable anesthesia supplies.

Best Practices for Use and Maintenance

  • Store unopened circuits in a clean, dry, temperature-controlled location according to the package instructions.
  • Rotate inventory by expiration date and use older acceptable stock before newer stock.
  • Keep the circuit in its original packaging until the anesthesia workstation is being prepared.
  • Verify every connection before patient use, including the mask, filter, breathing bag, elbows, machine connection, and gas sampling line.
  • Complete all required anesthesia machine and breathing-circuit checks before beginning the procedure.
  • Select the mask according to the patients facial anatomy rather than relying only on general adult sizing.
  • Support the circuit appropriately to prevent its weight from pulling on the patient interface or airway device.
  • Avoid placing equipment, bedding, or positioning devices on the tubing because compression may restrict gas flow.
  • Observe the circuit continuously for condensation, obstruction, kinking, leakage, disconnection, contamination, or damage.
  • Do not attempt to clean, sterilize, reprocess, or reuse a disposable single-patient anesthesia circuit.
  • Document product lot information when required by facility policy or quality-control procedures.

Regulatory and Safety Information

The Smiths Medical 384006 is a professional-use anesthesia circuit and should be selected, assembled, tested, and monitored only by personnel trained in anesthesia breathing systems and respiratory gas monitoring. It is not intended for unsupervised consumer use.

Confirm the products latex information on the current packaging before use. Because the product description identifies a Portex latex configuration, clinicians should assess the patient for known or suspected latex sensitivity and follow institutional latex-safety procedures. A latex-free alternative should be selected when clinically required.

Do not use the circuit if any component appears damaged, contaminated, incorrectly assembled, loose, obstructed, or incompatible with the intended equipment. A complete pre-use breathing-system test is necessary to identify leaks, blocked tubing, incorrect connections, or equipment malfunctions before the patient is connected.

Single-patient-use products should not be reused or reprocessed. Reuse can compromise material integrity, connector performance, cleanliness, and overall system reliability while increasing the risk of cross-contamination. Dispose of the circuit according to local regulations and the healthcare facilitys procedures for contaminated medical waste.

Always refer to the current manufacturer instructions for complete indications, warnings, precautions, contraindications, storage conditions, and operating requirements.

How to Order

Select the Smiths Medical 384006 CIRCUIT ANESTHESIA ADULT 25.4MMDIA 40INL SINGLE-LIMB GAS SAMPLING ELBOW/GAS SAMPLING PORT ELBOW FILTER 3L BAG MASK LARGE ADULT 10FTL MALE/MALE GAS SAMPLING LINE PORTEX LATEX DISPOSABLE (20/CS) and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

```

Related Products