(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 386001 - CIRCUIT ANESTHESIA ADULT 25.4MMDIA 60INL SINGLE-LIMB GAS SAMPLING ELBOW/GAS SAMPLING PORT ELBOW FILTER 3L BAG PORTEX LATEX DISPOSABLE (15/CS)

Smiths Medical # 386001 - CIRCUIT ANESTHESIA ADULT 25.4MMDIA 60INL SINGLE-LIMB GAS SAMPLING ELBOW/GAS SAMPLING PORT ELBOW FILTER 3L BAG PORTEX LATEX DISPOSABLE (15/CS)
Part Number Smiths Medical 386001
SKU Number CIA1073339
Sell Unit CASE
Ships Within Special Order
List Price $170.62
Enter a valid quantity
Product Description

Smiths Medical 386001 - CIRCUIT ANESTHESIA ADULT 25.4MMDIA 60INL SINGLE-LIMB GAS SAMPLING ELBOW/GAS SAMPLING PORT ELBOW FILTER 3L BAG PORTEX LATEX DISPOSABLE (15/CS)

The Smiths Medical 386001 anesthesia circuit is a disposable adult breathing circuit designed for use during anesthesia delivery and supported ventilation procedures. This single-limb circuit features a 25.4 mm diameter and a 60-inch length, providing practical reach between the patient and compatible anesthesia equipment.

The circuit configuration includes a gas-sampling elbow, gas-sampling port elbow, filter, and 3-liter breathing bag. These integrated components support respiratory gas monitoring, airway connection, filtration, and manual ventilation within a streamlined disposable setup. The product is supplied under the Portex line in cases containing 15 circuits.

Key Benefits

  • Single-limb adult anesthesia circuit for efficient breathing-system setup
  • 60-inch circuit length provides flexibility when positioning anesthesia equipment
  • 25.4 mm diameter supports the specified adult breathing-circuit configuration
  • Gas-sampling elbow and gas-sampling port elbow facilitate respiratory gas monitoring
  • Included filter supports contamination-control protocols within the breathing pathway
  • 3-liter breathing bag supports manual ventilation and visual assessment of breathing-system activity
  • Disposable construction helps reduce cleaning and reprocessing requirements
  • Complete component configuration can simplify preparation before anesthesia procedures
  • Packaged 15 circuits per case for hospital and surgical-center inventory management

Compatibility and Applications

The Smiths Medical 386001 circuit is intended for adult anesthesia applications requiring a single-limb breathing system with gas-sampling capability, filtration, and a 3-liter breathing bag. It may be used in operating rooms, ambulatory surgery centers, procedural suites, and other controlled clinical environments where anesthesia gases or assisted ventilation are administered.

Before use, clinicians should confirm compatibility with the anesthesia machine, ventilator, airway device, gas-monitoring line, connectors, and institutional breathing-system configuration. All connections should match the dimensions and performance requirements specified by the equipment manufacturers.

Usage Guidelines

  1. Inspect the package before opening and do not use the circuit if the packaging is damaged, opened, or compromised.
  2. Confirm that the circuit model, adult configuration, 60-inch length, 25.4 mm diameter, filter, elbows, sampling ports, and 3-liter bag match the planned procedure.
  3. Remove the circuit using appropriate infection-control practices.
  4. Connect the circuit securely to compatible anesthesia equipment and the selected patient airway interface.
  5. Attach the gas-sampling line to the designated sampling port according to the monitor manufacturer's instructions.
  6. Check that the filter and breathing bag are correctly positioned and securely connected.
  7. Perform the anesthesia machine and breathing-system leak tests required by the facility before connecting the circuit to the patient.
  8. Monitor circuit pressure, airway resistance, gas sampling, ventilation, and bag movement throughout the procedure.
  9. Dispose of the complete single-use circuit according to facility policy after the procedure.

Certifications and Safety Standards

The Smiths Medical 386001 anesthesia circuit should be used in accordance with the manufacturer's instructions, applicable medical-device regulations, anesthesia equipment requirements, and the healthcare facility's clinical policies. Users should review the current product label and packaging for regulatory status, manufacturing information, storage requirements, expiration dating, and any applicable standards or certifications.

Only clinicians trained in anesthesia breathing systems, airway management, respiratory monitoring, and assisted ventilation should select and use this product. Product availability and regulatory clearance may vary by market.

Comparison with Competitors

Compared with basic anesthesia circuits that require separate accessories, the Smiths Medical 386001 combines a single-limb breathing circuit, gas-sampling connections, filter, and 3-liter breathing bag in one disposable configuration. This may reduce the number of separately sourced components needed during room preparation.

When comparing this circuit with alternatives, healthcare facilities should evaluate circuit design, diameter, length, connector compatibility, sampling-port placement, filter specifications, bag capacity, packaging quantity, latex information, clinical workflow, and total procedural cost. Selection should be based on equipment compatibility and the requirements of the intended anesthesia technique rather than on price alone.

Typical User Profile and Application Scenarios

This adult anesthesia circuit is suitable for anesthesiologists, certified registered nurse anesthetists, anesthesia assistants, operating-room nurses, respiratory therapists, and other qualified healthcare professionals. It may be selected for scheduled surgery, outpatient procedures, diagnostic interventions, and other cases requiring an adult single-limb anesthesia breathing circuit.

The 60-inch length may be useful when additional separation is needed between the patient and the anesthesia machine. The integrated gas-sampling components support procedures in which continuous respiratory gas monitoring is required, while the filter and 3-liter bag provide essential breathing-system functions within the specified configuration.

Best Practices for Use and Maintenance

  • Store unopened circuits in a clean, dry area within the temperature and humidity limits shown on the packaging.
  • Rotate inventory by expiration date and inspect each package before use.
  • Verify all circuit components and connections before beginning anesthesia.
  • Perform a complete leak and function test after assembling the breathing system.
  • Position the circuit to prevent excessive pulling, twisting, compression, or accidental disconnection.
  • Keep the gas-sampling port accessible and confirm that the sampling line is not kinked or obstructed.
  • Monitor for condensation, blockage, increased resistance, leaks, or changes in ventilation performance.
  • Do not reuse, clean, resterilize, or reprocess a circuit labeled for single use.
  • Maintain an appropriate backup breathing circuit and ventilation method according to facility protocol.

Regulatory and Safety Information

The Smiths Medical 386001 is a professional-use medical device intended for use in appropriately equipped clinical settings. Clinicians must confirm the correct circuit configuration and conduct all required anesthesia machine, ventilation, and leak checks before patient use.

Because the product description identifies the circuit as a Portex latex disposable product, users should review the current packaging for specific latex and natural rubber information before use, particularly when treating patients or staff with known or suspected latex sensitivity. Do not rely solely on catalog descriptions when assessing material-related precautions.

Do not use the circuit if it is damaged, contaminated, expired, incorrectly assembled, or incompatible with the connected equipment. During use, continuously monitor the patient, airway pressure, delivered ventilation, respiratory gases, oxygenation, and circuit integrity. Follow local regulations and facility procedures when disposing of used breathing circuits and potentially contaminated medical waste.

How to Order

Select the Smiths Medical 386001 CIRCUIT ANESTHESIA ADULT 25.4MMDIA 60INL SINGLE-LIMB GAS SAMPLING ELBOW/GAS SAMPLING PORT ELBOW FILTER 3L BAG PORTEX LATEX DISPOSABLE (15/CS) and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products