Welch-Allyn DS44-MC - DuraShock DS44 Integrated Aneroid Sphygmomanometer; Gear Free, Shock Resistant, 5-Year Calibration Warranty; Inflation Bulb and Valve; Four-Cuff Kit: Size-09 (Child Print) to Size-12; FlexiPort Reusable, 1-Tube Cuffs; Qty. 4

Welch-Allyn # DS44-MC - DuraShock DS44 Integrated Aneroid Sphygmomanometer; Gear Free, Shock Resistant, 5-Year Calibration Warranty; Inflation Bulb and Valve; Four-Cuff Kit: Size-09 (Child Print) to Size-12; FlexiPort Reusable, 1-Tube Cuffs; Qty. 4
Part Number Welch-Allyn DS44-MC
SKU Number CIA2027803
Sell Unit EACH
Ships Within 24 Hours
List Price $290.39
Enter a valid quantity
Product Description

Welch-Allyn DS44-MC - DuraShock DS44 Integrated Aneroid Sphygmomanometer; Gear Free, Shock Resistant, 5-Year Calibration Warranty; Inflation Bulb and Valve; Four-Cuff Kit: Size-09 (Child Print) to Size-12; FlexiPort Reusable, 1-Tube Cuffs; Qty. 4

Bronze Series DS44 Integrated and Pocket Aneroids

Welch Allyn DuraShock DS44 Integrated Aneroid Sphygmomanometer; Gear Free, Shock Resistant, 5-Year Calibration Warranty; Inflation Bulb and Valve; Four-Cuff Kit: Size-09 (Child Print) to Size-12; FlexiPort Reusable, 1-Tube Cuffs; Qty. 4

This integrated-style gauge features a FlexiPort cuff-mounted design that's compact and lightweight. In use, the gauge can be rotated to any orientation desired by the clinician. With gear-free DuraShock technology, you can count on the DS44 Integrated Aneroid to remain in calibration longer than traditional aneroids, providing more accurate readings over time and a lower lifetime cost, helping to improve practice efficiencies and your bottom line.

  • Gear-free DuraShock technology
  • Certified accuracy to +/- 3 mmHg
  • Unsurpassed reliability with a unique integrated, cuff-mounted design
  • Withstands a 30" drop, AAMI's standard shock resistant requirement
  • Gauge rotates 360 degree, for easy viewing from any angle
  • Gauge snaps directly into cuff for quick cuff changes
  • Laser-engraved dial face for accuracy
  • 10-year calibration warranty
  • Latex-free for safety

Intended use

Welch Allyn non-automated sphygmomanometers are noninvasive blood pressure measurement devices intended for use in conjunction with an inflatable cuff and stethoscope to determine blood pressure in pediatric through adult patients.

Operation

Blood pressure measurements can be affected by the position of the patient and their physiologic condition. Before beginning a procedure, ensure that the patient rests for at least five minutes, has support of their back and feet, and does not cross their legs. Passively support the patients lower arm and keep the upper arm at heart level. The procedure needs to take place in a quiet environment with no talking. Failure to follow these recommendations can result in inaccurate blood pressure measurements.

  • Select cuff size appropriate for the patients arm circumference. The applicable range, in centimeters, is printed on each cuff.
    NOTE: The "Artery Index Marker" on the cuff should fall within the "Range" indicated on FlexiPort cuffs. The "Index Edge" on the cuff should fall within the Range indicated on Two-Piece Reusable cuffs. If the artery index marker or index edge falls short of the range, use a larger cuff to ensure accurate results. If the artery index marker or index edge is past the range, use a smaller cuff to ensure accurate results.
  • Wrap the cuff around the arm with the artery index marker located over the brachial artery and with the lower edge of the cuff 2.5 cm above the bend in the elbow.
  • Inflate cuff rapidly to a level 30 mm Hg above estimated (or palpatory) systolic pressure.
  • Partially open the valve to allow deflation at a rate of 2 to 3 mm Hg per second. As the pressure falls, note systolic pressure and diastolic pressure detected with your stethoscope.
  • Rapidly release the remaining pressure and record measurements immediately. After a minimum of 30 seconds, repeat the above steps for a second reading.

Operational Guidelines

The operator should have a direct view, and be within a meter, of the gauge during measurement. For manual blood pressure measurements, K5 is recommended for adult patients and K4 for pediatric patients ages 3 to 12. For pregnant females, clinician should use K5 , unless sounds are audible with a deflated cuff, in which case K4 should be used. NOTE: K5 is the point at which the Korotkoff sounds cannot be heard. K4 is the change in the tones heard from a clear sound to a muffled sound.

Welch Allyn DuraShock Technology

With gear-free DuraShock technology, you can count on the DS58 aneroid to remain in calibration longer than traditional aneroids, providing more accurate readings over time and a lower lifetime cost, helping to improve practice efficiencies and your bottom line.

Welch Allyns complete line of aneroid sphygmomanometers incorporating our shock-resistant DuraShock technology offers practical benefits compared to traditional aneroid sphygmomanometers. With gear-free DuraShock technology, you can count on Welch Allyn gauges to:

  • Remain in calibration longer than traditional blood pressure gauges, providing you with readings that maintain accuracy over time.
  • Not need to be replaced as often as traditional aneroids, giving you a lower lifetime cost.
  • Be capable of passing AAMIs shock resistant specification of surviving a 76 cm drop onto a hard surface and remaining in calibration.