(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD 406087 - Epidural Tray with 18G x 3 1/2 Inch Perisafe Weiss Epidural Needle, Glass LOR Syringe, Lidocaine, Epinephrine, and Sodium Chloride, 10/CS

BD  # 406087 - Epidural Tray with 18G x 3 1/2 Inch Perisafe Weiss Epidural Needle, Glass LOR Syringe, Lidocaine, Epinephrine, and Sodium Chloride, 10/CS
Part Number BD 406087
SKU Number CIA8042339
Sell Unit CASE
Ships Within Special Order
List Price $637.82
Enter a valid quantity
Product Description

BD 406087 - Epidural Tray with 18G x 3 1/2 Inch Perisafe Weiss Epidural Needle, Glass LOR Syringe, Lidocaine, Epinephrine, and Sodium Chloride, 10/CS

The BD 406087 Epidural Tray is a sterile, disposable epidural single-shot specialty tray designed for professional anesthesia, labor and delivery, surgical, and pain management environments. It includes an 18G x 3 1/2 inch BD Perisafe Weiss epidural needle with fixed wings, a 5 mL BD Epilor glass loss-of-resistance syringe with metal BD Luer-Lok tip, lidocaine HCL 1% 5 mL, lidocaine HCL 1.5% with epinephrine 1:200,000 5 mL, sodium chloride 0.9% 10 mL, and supporting preparation components for epidural procedures. BD lists this product as an epidural single-shot specialty tray with sterile contents and EO sterilization. :contentReference[oaicite:0]{index=0}

This tray helps clinicians prepare for epidural procedures by organizing commonly required components into one sterile setup. The Perisafe Weiss epidural needle supports epidural access, while the Epilor glass LOR syringe is used by trained anesthesia professionals during the loss-of-resistance technique to help identify the epidural space. The included local anesthetic, epinephrine-containing lidocaine, and saline components support procedure preparation according to medication labeling, patient assessment, clinician judgment, and facility protocol.

Key Benefits

  • Complete epidural tray format helps reduce the need to gather multiple separate components before the procedure.
  • 18G x 3 1/2 inch BD Perisafe Weiss epidural needle with fixed wings supports controlled handling during epidural access workflows.
  • 5 mL BD Epilor glass LOR syringe supports loss-of-resistance technique during epidural space identification.
  • Includes lidocaine HCL 1%, lidocaine HCL 1.5% with epinephrine 1:200,000, and sodium chloride 0.9% for compatible procedural use.
  • Includes a 20 mL BD Luer-Lok syringe, 18G x 1.5 inch 5 micron blunt-tip filter needle, 18G x 1.5 inch needle, 21G x 1.5 inch needle, 27G x 1.25 inch needle, and 3 mL BD Luer-Lok syringe as part of BDs listed configuration. :contentReference[oaicite:1]{index=1}
  • Clear plastic fenestrated drape supports sterile field setup during epidural procedures.
  • Sterile, disposable tray design supports infection control practices when used with strict aseptic technique.
  • Case quantity of 10 supports inventory planning for anesthesia departments, operating rooms, and labor and delivery units. :contentReference[oaicite:2]{index=2}

Compatibility and Applications

The BD 406087 is designed for epidural single-shot procedures performed by trained anesthesia professionals. It is suitable for hospitals, operating rooms, labor and delivery units, ambulatory surgery centers, pain management clinics, and other procedural environments where an epidural anesthesia setup may be clinically indicated.

BD lists this tray with a luer hub anesthesia needle, 20 mL BD Luer-Lok syringe, 5 mL BD Epilor glass LOR syringe, povidone-iodine topical solution, prep sponge-sticks, and clear plastic fenestrated drape. These components help support common sterile epidural procedure workflows and standardize tray setup across clinical teams. :contentReference[oaicite:3]{index=3}

Usage Guidelines

  • Use only by trained and qualified healthcare professionals experienced in epidural anesthesia techniques.
  • Inspect the tray packaging before use and do not use if the sterile barrier is damaged, opened, expired, or compromised.
  • Confirm the product number, needle gauge, needle length, medication contents, expiration date, and procedure requirements before opening.
  • Use strict aseptic technique during preparation, skin antisepsis, draping, needle handling, loss-of-resistance technique, and medication administration.
  • Review all included medications for concentration, expiration date, contraindications, allergy risk, preservative status where applicable, and patient-specific suitability before use.
  • Use the filter needle, injection needles, LOR syringe, epidural needle, and medication components only according to manufacturer instructions, medication labeling, anesthesia protocol, and facility policy.
  • Do not reuse, reprocess, or resterilize tray components.
  • Dispose of used needles, syringes, medication containers, and contaminated components according to sharps and regulated medical waste procedures.

Certifications, Safety Standards, and Regulatory Approvals

BD lists the 406087 as a sterile, disposable epidural single-shot specialty tray sterilized by EO. The official BD specification lists GTIN each 00382904060879, GTIN case 50382904060874, and 10 units per case. :contentReference[oaicite:4]{index=4}

BD also lists a total shelf life of up to 2 1/2 years depending on component expiration dates. Storage guidance includes room temperature conditions of 20 to 25 degrees C, permitted excursions from 15 to 30 degrees C, and protection from freezing. This temperature-sensitive guidance is important for maintaining medication integrity, tray readiness, and supply chain compliance. :contentReference[oaicite:5]{index=5}

Comparison with Competitor Products

The BD 406087 is best compared with epidural single-shot trays from manufacturers such as B Braun, Smiths Medical, ICU Medical, and other anesthesia tray suppliers. Compared with building a setup from separate components, this BD tray provides a standardized sterile configuration that may reduce preparation time, support consistent procedural setup, and simplify purchasing for anesthesia departments.

Compared with continuous epidural trays, the BD 406087 is configured as an epidural single-shot tray and does not include an epidural catheter. This makes it more appropriate for single-shot epidural workflows rather than continuous catheter-based epidural analgesia. :contentReference[oaicite:6]{index=6}

Compared with BD trays that include a 17G epidural needle, this model includes an 18G x 3 1/2 inch Perisafe Weiss epidural needle. Compared with trays that include only lidocaine HCL 1% and saline, this configuration also includes lidocaine HCL 1.5% with epinephrine 1:200,000, giving clinicians an expanded medication setup when clinically appropriate.

Typical User Profile and Application Scenarios

The typical users of the BD 406087 include anesthesiologists, certified registered nurse anesthetists, anesthesia assistants where permitted, pain management physicians, and trained operating room, labor and delivery, or procedural support teams.

This tray is most relevant in clinical scenarios requiring a sterile epidural single-shot setup with an 18G x 3 1/2 inch Weiss epidural needle, glass LOR syringe, lidocaine, epinephrine-containing lidocaine, sodium chloride, filter needle, skin prep, and clear fenestrated drape. Common use environments include labor and delivery anesthesia support, surgical anesthesia workflows, perioperative pain management, outpatient procedural anesthesia, and pain management settings where the clinician determines that epidural technique is appropriate.

Best Practices for Use and Maintenance

  • Store trays according to BDs stated temperature guidance and protect them from freezing.
  • Rotate stock by earliest expiration date because total shelf life may depend on individual component expiration dating.
  • Keep trays in original packaging until ready for use.
  • Verify all medication labels, concentrations, and expiration dates before preparation or administration.
  • Maintain a sterile field throughout the procedure and discard any component if sterility is compromised.
  • Confirm that patient monitoring, emergency medications, and resuscitation support are available according to facility anesthesia policy.
  • Use the filter needle, injection needles, LOR syringe, and epidural needle only for their intended procedural roles.
  • Do not substitute tray components without clinician approval and facility protocol alignment.
  • Dispose of all used sharps immediately in an approved sharps container.

Regulatory and Safety Information

The BD 406087 is intended for professional medical use in epidural anesthesia workflows. Epidural procedures involve significant clinical risk and should only be performed by trained clinicians following institutional policy, patient assessment, medication labeling, and accepted anesthesia practice standards.

Do not use this tray if the package is damaged, if any component is missing or compromised, if medication labeling is unclear, if the product is expired, or if the tray configuration does not match the intended procedure. The included lidocaine HCL 1%, lidocaine HCL 1.5% with epinephrine 1:200,000, and sodium chloride 0.9% should be used only when clinically appropriate and according to medication labeling and facility protocol.

How to Order

Select the BD 406087 Epidural Tray: 18G x 3" Perisafe Tuohy (Weiss) Epidural Needle, 5mL Epilor Glass Syringe LOR Luer Slip Metal Tip, Lidocaine HCL (1%) 5mL, Lidocaine HCL (1.5%) with Epi (1:200,000) 5mL, Sodium Chloride (0.9%) 10mL, Clear Drape (Rx), 10/cs (Temp Sensitive) and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, availability confirmation, or further assistance, contact CIA Medical customer service at (312) 275-5850 or use the contact form on this page.

Related Products