(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD 406151 - Epidural Tray with 17G Perisafe Weiss Epidural Needle, 19G Spring-Wound Catheter and Epilor Glass LOR Syringe

BD  # 406151 - Epidural Tray with 17G Perisafe Weiss Epidural Needle, 19G Spring-Wound Catheter and Epilor Glass LOR Syringe
Part Number BD 406151
SKU Number CIA8041220
Sell Unit CASE
Ships Within Special Order
List Price $1,119.93
Enter a valid quantity
Product Description

BD 406151 - Epidural Tray with 17G Perisafe Weiss Epidural Needle, 19G Spring-Wound Catheter and Epilor Glass LOR Syringe

The BD 406151 Epidural Tray is a comprehensive sterile procedure kit designed for epidural anesthesia and pain management procedures. This tray includes a 17G x 3" Perisafe Weiss epidural needle with fixed wings, a 19G spring-wound closed-end epidural catheter, a 5 mL Epilor glass loss-of-resistance syringe with Luer-Lok metal tip, Sodium Chloride 0.9% 10 mL, Lidocaine HCL 1% 5 mL, and Lidocaine HCL 1.5% 5 mL.

Manufactured by BD, a trusted leader in regional anesthesia solutions, this tray is designed to support efficient setup, accurate epidural space identification, reliable catheter placement, and consistent sterile technique in surgical, obstetric, and pain management environments.

Key Benefits

The BD 406151 Epidural Tray provides essential epidural components and commonly used procedural solutions in one organized sterile package, helping reduce preparation time and improve workflow efficiency.

The Perisafe Weiss epidural needle supports controlled epidural access, while the spring-wound epidural catheter provides flexibility, kink resistance, and reliable medication delivery.

The Epilor glass loss-of-resistance syringe with metal tip supports precise identification of the epidural space. Included saline and lidocaine solutions help streamline procedural readiness.

Compatibility and Applications

The BD 406151 Epidural Tray is designed for epidural anesthesia, labor analgesia, postoperative pain management, regional anesthesia, and pain control procedures requiring epidural catheter placement.

It is commonly used in hospitals, labor and delivery units, operating rooms, surgical centers, and pain management clinics.

Usage Guidelines

Confirm that the tray packaging is intact and sterile before use. Prepare the patient and procedural site according to institutional aseptic protocols.

Use the included epidural needle, catheter, loss-of-resistance syringe, saline, and lidocaine solutions according to accepted epidural anesthesia techniques and facility guidelines. Confirm correct catheter placement before medication administration.

Dispose of all sharps and used components immediately after the procedure according to approved medical waste and sharps disposal protocols.

Certifications and Safety Standards

The BD 406151 Epidural Tray is manufactured under ISO-certified quality management systems and Good Manufacturing Practices.

The product complies with applicable regulatory requirements, including FDA clearance and CE marking where applicable, supporting consistent safety, quality, and clinical performance.

Comparison with Competitors

Compared with basic epidural kits, the BD 406151 tray offers a more complete procedural configuration with a Perisafe Weiss epidural needle, spring-wound catheter, Epilor glass LOR syringe, saline, and lidocaine solutions.

BDs consistent manufacturing standards help ensure dependable component quality, procedural reliability, and efficient anesthesia workflow.

Typical User Profile and Application Scenarios

The BD 406151 Epidural Tray is intended for anesthesiologists, certified registered nurse anesthetists, obstetric anesthesia teams, and pain management specialists.

Typical scenarios include labor epidurals, postoperative analgesia, surgical epidural anesthesia, regional pain control, and epidural catheter placement in hospital or specialty care settings.

Best Practices for Use and Maintenance

Use the tray as a sterile, single-use procedural kit and maintain strict aseptic technique throughout the procedure.

Confirm epidural needle and catheter placement using accepted clinical methods before medication administration. Monitor patients according to institutional anesthesia and recovery protocols.

Store the tray in a clean, dry environment and inspect packaging before use to confirm sterility and product integrity.

Regulatory and Safety Information

The BD 406151 Epidural Tray is intended for professional use by trained clinicians experienced in epidural anesthesia procedures.

Users should follow institutional protocols for epidural catheter placement, medication handling, infection prevention, and sharps safety. The product is manufactured to meet recognized medical device safety and quality standards.

How to Order

Select the BD 406151 Epidural Tray with 17G Perisafe Weiss Epidural Needle, 19G Spring-Wound Epidural Catheter and Epilor Glass LOR Syringe and add it to your cart. Complete checkout with your preferred shipping and payment options.

For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.