BD 406308 - Epidural Anesthesia Support Tray with Filter Needle, Luer Syringes, Epilor LOR Syringe, Lidocaine HCL 1%, and Sodium Chloride 0.9%

BD  # 406308 - Epidural Anesthesia Support Tray with Filter Needle, Luer Syringes, Epilor LOR Syringe, Lidocaine HCL 1%, and Sodium Chloride 0.9%
Part Number BD 406308
SKU Number CIA8042380
Sell Unit CASE
Ships Within Special Order
List Price $474.16
Enter a valid quantity
Product Description

BD 406308 - Epidural Anesthesia Support Tray with Filter Needle, Luer Syringes, Epilor LOR Syringe, Lidocaine HCL 1%, and Sodium Chloride 0.9%

The BD 406308 Support Tray is a sterile, disposable epidural anesthesia support tray designed for professional anesthesia workflows. It includes essential preparation and support components such as needles, syringes, a BD Epilor plastic loss-of-resistance syringe, Lidocaine HCL 1% 5 mL, and Sodium Chloride 0.9% 10 mL for use in appropriate clinical settings.

BD identifies SKU 406308 as a BD Epidural Anesthesia Support Tray with Lidocaine HCL 1% 5 mL. BD lists this tray as an epidural single-shot support tray, with no epidural needle and no epidural catheter included, making it a support configuration rather than a full epidural catheter placement kit. :contentReference[oaicite:0]{index=0}

The tray includes a 7 mL BD Epilor plastic LOR Luer slip tip syringe, 10 mL BD Luer-Lok syringe, 3 mL BD Luer-Lok syringe, 18G x 1.5 inch 5 micron blunt-tip filter needle, Lidocaine HCL 1% 5 mL, Sodium Chloride 0.9% 10 mL, catheter support pad, prep sponge-sticks, and blue paper fenestrated drape according to BDs product specifications. :contentReference[oaicite:1]{index=1}

Key Benefits

  • Organized support tray format helps streamline anesthesia setup and preparation.
  • Includes commonly used syringes and medication preparation components for epidural support workflows.
  • 7 mL BD Epilor plastic LOR syringe supports loss-of-resistance technique when used by trained anesthesia professionals.
  • 18G x 1.5 inch blunt-tip filter needle with 5 micron filter supports medication preparation from appropriate containers. :contentReference[oaicite:2]{index=2}
  • BD blunt filter needles are designed to reduce needlestick injury risk during medication preparation compared with conventional hypodermic needles and include a 5 micron membrane designed to help prevent large particles from being drawn into the syringe when preparing medications from ampoules. :contentReference[oaicite:3]{index=3}
  • Includes Lidocaine HCL 1% 5 mL and Sodium Chloride 0.9% 10 mL for compatible clinical use according to facility protocol. :contentReference[oaicite:4]{index=4}
  • Sterile, EO-sterilized, disposable configuration supports aseptic procedural preparation. :contentReference[oaicite:5]{index=5}
  • Case quantity of 10 supports inventory planning for hospitals, surgery centers, labor and delivery units, and anesthesia departments. :contentReference[oaicite:6]{index=6}

Compatibility and Applications

The BD 406308 is intended for anesthesia support workflows where clinicians require selected preparation components, syringes, a loss-of-resistance syringe, local anesthetic, saline, prep supplies, and draping components. Because BD lists the tray as having no epidural needle and no epidural catheter, facilities should pair it only with the appropriate separately supplied procedure needle, catheter, and related devices required by the planned procedure. :contentReference[oaicite:7]{index=7}

This support tray is commonly relevant for hospitals, operating rooms, labor and delivery units, pain management settings, ambulatory surgery centers, anesthesia departments, and procedure areas where standardized sterile anesthesia support supplies are needed.

Typical applications may include epidural support preparation, single-shot epidural support workflows, regional anesthesia setup, medication preparation, skin preparation, and sterile field organization when clinically appropriate and performed by trained personnel.

Usage Guidelines

  • Use only by trained anesthesia professionals or qualified clinicians following facility policy, medication labeling, and applicable clinical standards.
  • Inspect the sterile package before use and do not use the tray if packaging is damaged, opened, expired, wet, or compromised.
  • Confirm that the tray configuration matches the planned procedure and that required procedure needles, catheters, medications, monitoring equipment, and emergency supplies are available.
  • Verify all medications, concentrations, expiration dates, and patient allergies before use.
  • Use strict aseptic technique when opening the tray, preparing medications, and maintaining the sterile field.
  • Use the blunt filter needle only for medication preparation in accordance with manufacturer instructions and facility protocol.
  • Use Luer-Lok and Luer slip syringes only with compatible devices and connections.
  • Do not use the tray as a substitute for a complete epidural tray when an epidural needle or catheter is required.
  • Dispose of needles, syringes, and contaminated components according to sharps safety, medication waste, and regulated medical waste procedures.

Certifications, Safety Standards, and Regulatory Approvals

BD lists the BD 406308 tray as sterile, EO-sterilized, and disposable. The product has a case GTIN of 50382904063080 and an each GTIN of 00382904063085. BD also lists a total shelf life of up to 2.5 years, depending on component expiration dates. :contentReference[oaicite:8]{index=8}

BD specifies room temperature storage at 20C to 25C, with excursions permitted from 15C to 30C, and notes that the product should be protected from freezing. Healthcare facilities should verify current labeling, medication dating, component expiration, storage requirements, lot information, and regulatory status directly through BD, CIA Medical, or an authorized distributor before use. :contentReference[oaicite:9]{index=9}

Comparison with Competitor Products

The BD 406308 is best compared with anesthesia support trays from manufacturers such as B. Braun, Smiths Medical, ICU Medical, Halyard, and other procedural tray suppliers. Compared with a full epidural tray, this BD configuration is a support tray and does not include an epidural needle or epidural catheter, which may make it suitable for facilities that prefer to select procedure-specific needles and catheters separately.

Compared with assembling individual components from separate inventory locations, BD 406308 helps standardize setup by grouping key support items such as syringes, filter needle, LOR syringe, local anesthetic, saline, prep materials, and drape into one sterile tray configuration.

Compared with trays that do not include medication components, this tray includes Lidocaine HCL 1% 5 mL and Sodium Chloride 0.9% 10 mL, which may reduce setup steps when those components match the facilitys approved protocol. Facilities should still verify medication suitability, patient-specific requirements, and local formulary policy before use.

Typical User Profile and Application Scenarios

The typical users of the BD 406308 include anesthesiologists, certified registered nurse anesthetists, anesthesia assistants, pain management clinicians, labor and delivery anesthesia teams, operating room staff, and other trained healthcare professionals supporting sterile anesthesia procedures.

This tray is especially useful in clinical scenarios requiring a sterile anesthesia support setup with Lidocaine HCL 1%, Sodium Chloride 0.9%, Luer syringes, a BD Epilor LOR syringe, a blunt-tip filter needle, prep components, and a fenestrated drape. It may be selected when the facility already has separate procedure needles or catheters available and needs a standardized support tray.

Best Practices for Use and Maintenance

  • Store the tray at the temperature range specified by BD and protect it from freezing.
  • Rotate inventory by expiration date, especially because medication and component dating may determine the usable shelf life.
  • Keep the tray sealed in original packaging until ready for use.
  • Confirm the tray is complete before beginning procedure setup.
  • Check medication names, concentrations, expiration dates, and package integrity before administration.
  • Use the 18G blunt-tip filter needle for appropriate medication preparation tasks only, not for patient injection.
  • Maintain a sterile field and avoid unnecessary handling of sterile components.
  • Ensure sharps disposal containers are immediately available before opening needles and syringes.
  • Document medication use, lot information, and procedure details according to facility policy.
  • Train staff on the difference between support trays and complete epidural trays to prevent missing-procedure-component delays.

Regulatory and Safety Information

The BD 406308 is intended for professional clinical use in appropriate anesthesia settings. Because it contains medication and sterile procedural components, it should be handled only by qualified healthcare personnel following manufacturer instructions, medication labeling, facility policy, and applicable clinical guidelines.

Do not use the product if packaging is damaged, if the tray is expired, if medication containers are compromised, if required procedure components are missing, or if the tray configuration does not match the planned procedure. Needles and syringes are single-use items and must not be reused, resterilized, or shared between patients. Dispose of all sharps and contaminated materials in accordance with facility, OSHA, and regulated medical waste procedures.

How to Order

Select the BD 406308 Support Tray: 18G x 1" Filter Needle Blunt Tip, 25G x 1" Needle, 18G x 1" Needle Short Bevel, 3mL Syringe Luer-Lok, 10mL Syringe Luer-Lok, 5mL Syringe Luer Slip, 7mL Epilor Syringe LOR Plastic Luer Slip, Lidocaine HCL (1%) 5mL, Sodium Chloride (0.9%) 10 and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, availability confirmation, temperature-sensitive shipping questions, or further assistance, contact CIA Medical customer service at (312) 275-5850 or use the contact form on this page.

Related Products