(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD 305211 - Needle 18 Gauge x 1 Inch Thin Wall Blunt Fill Tip with 5 Micron Filter Latex-Free,100/BX, 10 BX/CS

BD  # 305211 - Needle 18 Gauge x 1 Inch Thin Wall Blunt Fill Tip with 5 Micron Filter Latex-Free,100/BX, 10 BX/CS
Part Number BD 305211
SKU Number CIA8008550
Sell Unit CASE
Ships Within Special Order
List Price $401.90
Enter a valid quantity
Product Description

BD 305211 - Needle 18 Gauge x 1 Inch Thin Wall Blunt Fill Tip with 5 Micron Filter Latex-Free,100/BX, 10 BX/CS

The BD 305211 Needle 18G x 1 Inch Thin Wall Blunt Fill Tip with 5 Micron Filter is a specialty needle designed for safe and efficient medication preparation during vial access and fluid transfer. Manufactured by Becton, Dickinson and Company, this needle features a blunt fill tip to reduce the risk of accidental needlestick injuries while drawing medications from vials.

The thin wall cannula design supports higher flow rates compared to standard wall needles, improving efficiency during fluid withdrawal. An integrated 5 micron filter helps reduce the transfer of particulate matter, supporting medication integrity during preparation. The product contains no natural rubber latex, making it suitable for latex-sensitive environments.

Manufacturer305211
ApplicationFilter Needle
Color CodeClear
Filter Type5 Micron Filter
Needle Point StyleBlunt
SterilitySterile

Key Benefits

The blunt fill tip enhances clinician safety by minimizing sharps injury risk during medication preparation. The thin wall construction allows faster fluid draw without increasing needle size, helping improve workflow efficiency in pharmacy and clinical settings.

The integrated 5 micron filter helps capture glass shards or particulate matter that may be present when accessing medication vials, supporting safer downstream administration. Latex-free construction supports broader compatibility with allergy-sensitive patient care protocols.

Compatibility and Applications

The BD 305211 needle is designed for use with standard Luer Lock syringes, providing a secure, leak-resistant connection during vial access and fluid transfer. It integrates seamlessly into medication preparation workflows without requiring additional adapters.

Common applications include withdrawing medications from glass ampules or vials, pharmacy compounding, IV medication preparation, and fluid transfer tasks in hospitals, outpatient clinics, infusion centers, and pharmacy environments.

Usage Guidelines

The needle should be attached securely to a compatible Luer Lock syringe using standard aseptic technique. The blunt fill tip is intended for vial access and medication preparation only and is not designed for patient injection.

After completing fluid transfer, the needle should be disposed of immediately in an approved sharps container. The product is intended for single use only to maintain sterility and filtration performance.

Certifications, Safety Standards, and Regulatory Approvals

The BD 305211 Needle is manufactured under strict quality management systems aligned with FDA medical device regulations and internationally recognized manufacturing standards. These controls ensure consistent filter performance, dimensional accuracy, and sterility.

Regulatory compliance confirms the products suitability for use in regulated healthcare and pharmacy environments across the United States.

Comparison with Competitor Products

Compared with standard sharp fill needles, the BD blunt fill needle offers improved safety by eliminating the sharp bevel during medication withdrawal. While some competitor blunt needles lack filtration, the integrated 5 micron filter in the BD 305211 provides an added layer of protection against particulate contamination.

Healthcare professionals often prefer BD blunt fill needles for their reliable filtration, efficient flow performance, and trusted manufacturing quality.

Typical User Profile and Application Scenarios

Typical users include pharmacists, pharmacy technicians, nurses, anesthesiology staff, and trained healthcare professionals involved in medication preparation and compounding.

The product is especially effective in hospital pharmacies, infusion centers, operating rooms, and clinical environments where safe vial access and particulate control are priorities.

Best Practices for Use and Maintenance

Best practice includes verifying that the needle is used only for medication preparation and not for injection. The needle should remain sealed until use and handled using proper aseptic technique.

Immediate disposal after use supports sharps safety and infection control policies. As a single-use device, no cleaning or maintenance is required.

Regulatory and Safety Information

The BD 305211 Needle 18 Gauge x 1 Inch Blunt Fill Tip with 5 Micron Filter is classified as a regulated medical device and complies with applicable FDA requirements. Its blunt design supports adherence to occupational safety guidelines aimed at reducing needlestick injuries.

Following manufacturer instructions and institutional protocols ensures safe, compliant use in all approved applications.

How to Order

The BD 305211 Needle 18G x 1 Inch Thin Wall Blunt Fill Tip with 5 Micron Filter Latex-Free is available for purchase through the CIA Medical website. Add the product to your cart and proceed through the secure checkout process.

For bulk purchasing, pharmacy pricing, or additional product assistance, contact CIA Medical customer service at 312 275 5850 or use the contact form available on this page for prompt support.