(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Carefusion A1411 - Achieve Biopsy Needle 14G x 11cm Precision Core Sample Needle for Soft Tissue Biopsy, 5/CS

Carefusion # A1411 - Achieve Biopsy Needle 14G x 11cm  Precision Core Sample Needle for Soft Tissue Biopsy, 5/CS
Part Number Carefusion A1411
SKU Number CIA7015905
Sell Unit CASE
Ships Within 2-3 Days
List Price $815.80
Enter a valid quantity
Product Description

Carefusion A1411 - Achieve Biopsy Needle 14G x 11cm Precision Core Sample Needle for Soft Tissue Biopsy, 5/CS

The Carefusion A1411 Achieve Biopsy Needle (14G x 11 cm) is a precision-engineered, soft tissue biopsy instrument designed to deliver consistent and accurate core samples with minimal patient trauma. Developed with a spring-loaded, fully automatic firing mechanism, this single-use biopsy device ensures precise penetration and retrieval of tissue, reducing procedural time and enhancing diagnostic accuracy. Its compact 14-gauge design provides a balanced combination of control and core sample size, making it ideal for use in multiple clinical scenarios.

The needle is primarily used in procedures requiring histological sampling of soft tissues, including breast, kidney, liver, lymph node, and prostate biopsies. The intuitive design supports radiologists, oncologists, and interventional physicians by simplifying the biopsy process while ensuring consistent performance.

ManufacturerA1411
ApplicationSoft Tissue Biopsy Needle
Color CodeWhite
Gauge14 Gauge
Handle MateriaPlastic Handle

Key Benefits

  • High-precision sampling: The 14G core and 11 cm shaft enable optimal tissue retrieval, producing high-integrity samples for pathological analysis.

  • Sterile, single-use format: Minimizes infection risk and cross-contamination, adhering to best-practice clinical protocols.

  • Spring-loaded action: Offers smooth, rapid deployment, reducing patient discomfort and improving user control.

  • Lightweight and ergonomic: Designed for ease of use during ultrasound or CT-guided procedures.

  • Time-saving: The pre-assembled, ready-to-use configuration streamlines setup and shortens overall procedure time.

Compatibility and Applications
This needle is compatible with most imaging-guided biopsy systems and is designed for use in:

  • Outpatient clinics and interventional radiology suites

  • Surgical centers and hospital operating rooms

  • Oncology departments for tumor sampling

  • Specialty diagnostic labs performing soft tissue analysis

The Achieve system is engineered to work seamlessly with imaging modalities like ultrasound, fluoroscopy, and CT, ensuring precision in deep or superficially located lesions.

Usage Guidelines

  • Confirm needle gauge and length before procedure.

  • Remove from sterile packaging only when ready to use.

  • Position needle using ultrasound or CT guidance for optimal targeting.

  • Trigger device only when tip is accurately placed within the lesion.

  • Dispose of properly in sharps container after single use.

Always refer to the manufacturers official instructions for full operational guidance, including contraindications, preparation steps, and troubleshooting.

Certifications, Safety Standards, and Regulatory Approvals

  • FDA Cleared: Ensures the product meets stringent US safety and performance standards.

  • CE Marked: Approved for use across European medical facilities, confirming conformity with health and safety regulations.

  • ISO 13485 Certified Manufacturing: Guarantees quality and reliability throughout the production process.

  • Latex-free and DEHP-free materials to support patient safety and reduce allergic reaction risks.

Comparison with Competitor Products
Compared to similar biopsy systems on the market such as the Bard Mission or Argon UltraCor, the Carefusion A1411 Achieve Biopsy Needle offers distinct advantages:

  • Faster spring mechanism and more intuitive operation

  • Greater control due to its ergonomic design

  • Sterile, individually packaged units that enhance procedural efficiency

  • Backed by the reputable Becton Dickinson (BD) brand, known for high-precision medical tools

These attributes make it the preferred choice for clinicians requiring reliable tissue acquisition with minimal error margin.

Typical User Profile and Application Scenarios
This biopsy needle is designed for use by:

  • Interventional radiologists

  • Oncologists

  • Diagnostic imaging technicians

  • Pathologists performing guided biopsies

Application scenarios include breast lump assessment, liver mass evaluation, prostate cancer diagnostics, and lymph node sampling in suspected lymphoma cases. The needle is ideal in both hospital and ambulatory care settings.

Best Practices for Use and Maintenance

  • Always verify product integrity before use.

  • Store in a dry, sterile environment, away from extreme temperatures.

  • Do not re-use under any circumstancesintended for one-time sterile use only.

  • Ensure the firing mechanism is tested on a sample material or training pad during staff onboarding.

  • Follow OSHA sharps disposal protocols to maintain staff and patient safety.

Regulatory and Safety Information
The A1411 Achieve Biopsy Needle complies with all applicable healthcare industry regulations. Its FDA and CE approvals validate its safety for patient use. The device contains no natural rubber latex and is compliant with RoHS and REACH standards, supporting both environmental and human health safety.

How to Order
To purchase the Carefusion A1411 Achieve Biopsy Needle 14G x 11 cm:

  • Click Add to Cart to begin the standard checkout process through CIA Medicals secure platform.

  • For larger volume orders, group purchasing options, or pricing inquiries, contact CIA Medical customer service at (312) 275-5850 or submit your request using the Contact Form on this page.

Bulk pricing, expedited shipping options, and product support are available to meet institutional needs across hospitals, surgery centers, and research labs.

Let me know if youd like a version with product image placement suggestions or layout ideas for an eCommerce product page.

Related Products