(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Progeny-Midmark 30-08041 - POWER SUPPLY CONTRL BOARD

POWER SUPPLY CONTRL BOARD
Part Number Progeny-Midmark 30-08041
SKU Number CIA2431475
Sell Unit EACH
Ships Within Special Order
List Price $944.08
Enter a valid quantity
Product Description

Progeny-Midmark 30-08041 - POWER SUPPLY CONTRL BOARD

The Midmark 30-08041 Power Supply Control Board is a critical electronic component engineered to regulate and distribute electrical power within compatible Midmark medical examination tables and procedure chairs. Designed for dependable performance in clinical environments, this control board manages voltage flow to motors, actuators, and integrated accessories to ensure consistent operation during patient positioning and examination procedures.

Healthcare facilities depend on reliable equipment uptime, and the power supply control board plays a central role in maintaining operational stability. This replacement board restores functionality to tables experiencing power irregularities, intermittent movement, or non-responsive controls. Manufactured to precise specifications, it integrates seamlessly into the existing system architecture without requiring modification to wiring or control interfaces.

Key Benefits

Ensures stable and regulated electrical distribution to examination table components, preventing sudden shutdowns and inconsistent motion.

Restores original equipment performance by replacing worn or damaged electronic control circuitry.

Supports smooth actuator movement, enhancing patient comfort and clinician efficiency during positioning.

Reduces maintenance downtime by providing a direct-fit replacement compatible with factory wiring harnesses.

Helps extend equipment lifespan by preventing voltage fluctuations that can damage motors and electronic accessories.

Compatibility and Applications

The Midmark 30-08041 Power Supply Control Board is designed for use in compatible Midmark examination tables and procedure chairs equipped with electronic positioning systems. It is commonly installed in outpatient clinics, physician offices, ambulatory surgical centers, urgent care facilities, and specialty treatment rooms where motorized patient positioning is essential.

Typical applications include general examinations, dermatology procedures, minor surgeries, diagnostic imaging preparation, and patient positioning during treatment. The board integrates with control panels, foot controls, and accessory modules that rely on regulated electrical input for proper operation.

Usage Guidelines

Installation should be performed by qualified biomedical technicians or trained service personnel familiar with medical equipment electronics. Before installation, disconnect the device from the electrical supply and confirm that stored power has dissipated.

Carefully remove the existing board while documenting connector orientation. Install the replacement board using the original mounting hardware and reconnect wiring harnesses according to manufacturer layout. After installation, perform a full functional test including height adjustment, backrest articulation, and accessory activation to verify proper operation.

Do not operate the table if abnormal sounds, irregular motion, or delayed response is observed after installation. Recheck connections and confirm correct voltage supply before returning equipment to clinical use.

Certifications and Safety Standards

Manufactured to meet medical equipment electrical safety expectations for clinical environments. The control board is designed to function within regulated voltage tolerances required for patient care equipment and supports safe grounding and circuit protection within compatible systems.

The component is engineered for integration with electrically powered medical furniture that complies with recognized healthcare equipment safety requirements.

Comparison with Competitors

Unlike generic aftermarket electronic boards, the Midmark 30-08041 is engineered specifically for compatible Midmark equipment, ensuring proper communication between control interfaces and actuators. Third party boards may provide power but often lack precise calibration required for synchronized motor control, resulting in jerky movement or incomplete positioning.

This original specification component maintains manufacturer performance standards, while generic alternatives may require wiring modifications or fail to support accessory functions such as programmable positioning or coordinated motor response.

Typical User Profile and Application Scenarios

Ideal for biomedical service departments responsible for maintaining powered examination tables in busy healthcare settings. Frequently used by maintenance teams in primary care clinics, specialty practices, and surgical preparation areas where reliable equipment function is necessary to maintain patient workflow.

It is particularly valuable in facilities experiencing high patient turnover where table failure can disrupt schedules and reduce operational efficiency. Replacement of the control board allows clinicians to continue using existing equipment without full table replacement.

Best Practices for Use and Maintenance

Regularly inspect wiring harnesses and connectors for signs of wear or looseness during routine maintenance. Maintain a clean interior environment inside the equipment housing to prevent dust accumulation around electronic components.

Avoid exposure to liquid spills near control panels and power connections. Periodically test table movement functions to detect early irregularities that may indicate electrical instability. Using proper surge protection within the facility electrical system can help prolong component life.

Regulatory and Safety Information

This component is intended for professional installation within medical equipment systems. Improper installation may result in equipment malfunction or safety risk. Always disconnect power before servicing. Only trained personnel should service powered medical furniture.

The board is designed exclusively as a replacement component for compatible systems and should not be modified or used outside intended applications.

How to Order

To order the Midmark 30-08041 Power Supply Control Board, contact CIA Medical customer support at (312) 275-5850. Provide the equipment model information to confirm compatibility and receive assistance with purchasing and availability.