(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 101/818/090 - Tracheostomy Tube, 9.0, Uncuffed, with Wedge and Decan Cap, Fenestrated, PVC

Tracheostomy Tube, 9.0, Uncuffed, with Wedge and Decan Cap, Fenestrated, PVC
Part Number Smiths Medical 101/818/090
SKU Number CIA8066885
Sell Unit EACH
Ships Within Special Order
List Price $86.54
Enter a valid quantity
Product Description

Smiths Medical 101/818/090 - Tracheostomy Tube, 9.0, Uncuffed, with Wedge and Decan Cap, Fenestrated, PVC

The Smiths Medical 101/818/090 Tracheostomy Tube is a size 9.0 uncuffed, fenestrated tracheostomy tube designed to support effective airway management while promoting patient comfort and communication. Manufactured from high-quality medical-grade PVC, this tube provides a balance of flexibility and structural integrity, ensuring reliable performance in both acute and long-term care environments.

This model features a fenestrated design that allows airflow through the upper airway, facilitating speech and aiding in the natural breathing process. The inclusion of a wedge-shaped flange enhances stability and positioning, while the decannulation cap supports weaning protocols by enabling controlled airway transition. The tube is specifically developed for patients who do not require a cuff, making it suitable for spontaneous breathing and reduced airway obstruction scenarios.

Key Benefits

The fenestrated construction allows improved airflow through the vocal cords, enabling speech when clinically appropriate. This enhances patient quality of life and supports rehabilitation. The uncuffed design reduces pressure on the tracheal walls, minimizing the risk of tissue damage and making it suitable for long-term use.

The wedge-shaped neck flange provides secure positioning and comfort, reducing the likelihood of displacement. The included decannulation cap allows clinicians to assess readiness for tube removal by encouraging normal breathing through the upper airway.

The smooth PVC material ensures patient comfort while maintaining durability and resistance to kinking. The tubes design also allows for easy insertion and removal, supporting efficient clinical workflows.

Compatibility and Applications

This tracheostomy tube is compatible with standard 15 mm connectors, making it suitable for use with a wide range of ventilators, humidification systems, and respiratory support devices. It integrates seamlessly into hospital, long-term care, and home healthcare settings.

It is commonly used in patients who require airway access but do not need a cuffed tube, including those undergoing weaning from mechanical ventilation or those with stable airway conditions. The fenestrated design makes it particularly beneficial for patients in speech rehabilitation programs.

Applications include intensive care units, step-down units, rehabilitation centers, and home care environments where patient comfort and communication are priorities.

Usage Guidelines

The tracheostomy tube should be inserted by trained healthcare professionals following established clinical protocols. Proper sizing and patient assessment are essential to ensure optimal fit and performance. The fenestration should be aligned correctly to allow airflow through the upper airway.

The decannulation cap can be used during weaning trials under clinical supervision. Patients should be monitored closely for respiratory function and tolerance when using the cap.

Routine cleaning and inspection are recommended to maintain hygiene and device integrity. Any signs of damage, blockage, or wear should prompt immediate replacement.

Certifications and Safety Standards

This product is manufactured in compliance with international medical device standards, ensuring consistent quality and patient safety. It meets regulatory requirements for use in clinical environments and is produced under strict quality control processes.

The materials used are biocompatible and designed to minimize the risk of adverse reactions. The device undergoes rigorous testing to ensure performance, durability, and safety under various clinical conditions.

Comparison with Competitors

Compared to standard non-fenestrated tracheostomy tubes, this model offers enhanced patient communication and airflow through its fenestrated design. Unlike cuffed alternatives, it reduces pressure-related complications, making it more suitable for long-term use in stable patients.

The inclusion of both a wedge flange and a decannulation cap provides added versatility, allowing clinicians to manage patient care more effectively. Many competing products may not offer this combination of features in a single device.

The high-quality PVC construction ensures a balance between flexibility and strength, outperforming lower-grade materials that may compromise patient comfort or durability.

Typical User Profile and Application Scenarios

This tracheostomy tube is ideal for adult patients requiring airway management without the need for cuff inflation. It is commonly used in patients transitioning off mechanical ventilation, those with chronic respiratory conditions, or individuals undergoing speech rehabilitation.

Healthcare providers in hospitals, rehabilitation centers, and home care settings benefit from its ease of use and adaptability. It is particularly suited for scenarios where maintaining patient comfort and enabling communication are key priorities.

Caregivers and clinicians managing long-term tracheostomy patients will find this product effective in supporting both medical and quality-of-life outcomes.

Best Practices for Use and Maintenance

Regular cleaning and inspection are essential to maintain device performance and patient safety. The tube should be checked for blockages, cracks, or signs of wear before each use. Proper humidification should be maintained to prevent secretion buildup.

Secure fixation of the tube is important to prevent accidental displacement. The wedge flange should be positioned correctly to ensure stability and patient comfort.

During use of the decannulation cap, patients should be monitored closely for signs of respiratory distress. Any changes in breathing patterns should be addressed immediately by healthcare professionals.

Regulatory and Safety Information

This device is intended for use by trained healthcare professionals or under their supervision. It should be used in accordance with clinical guidelines and institutional protocols. Proper patient selection and monitoring are critical to ensure safe and effective use.

The product is single-use unless otherwise specified and should be disposed of according to medical waste regulations after use. Reuse or improper handling may compromise safety and performance.

All components are designed to meet safety standards for airway management devices, ensuring reliability in critical care settings.

How to Order

Select the Smiths Medical 101/818/090 Tracheostomy Tube, 9.0, Uncuffed, with Wedge and Decan Cap, Fenestrated, PVC, and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products