(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 101/818/100 - Tracheostomy Tube, 10.0, Uncuffed, with Wedge and Decan Cap, Fenestrated, PVC

Tracheostomy Tube, 10.0, Uncuffed, with Wedge and Decan Cap, Fenestrated, PVC
Part Number Smiths Medical 101/818/100
SKU Number CIA8066865
Sell Unit EACH
Ships Within Special Order
List Price $86.54
Enter a valid quantity
Product Description

Smiths Medical 101/818/100 - Tracheostomy Tube, 10.0, Uncuffed, with Wedge and Decan Cap, Fenestrated, PVC

The Smiths Medical 101/818/100 Tracheostomy Tube is designed to support effective airway management in patients requiring long-term or intermediate respiratory assistance. Featuring a 10.0 mm internal diameter, this uncuffed, fenestrated tracheostomy tube allows for improved airflow and phonation capabilities, making it suitable for patients transitioning toward independent breathing.

Constructed from high-quality medical-grade PVC, the tube offers a balance of flexibility and structural integrity, reducing the risk of irritation while maintaining consistent airway patency. The integrated wedge design enhances anatomical fit and stability, while the included decannulation cap supports weaning protocols and controlled breathing trials. The fenestrated design allows airflow through the upper airway, facilitating speech and natural breathing patterns when clinically appropriate.

Key Benefits

This tracheostomy tube is engineered to provide optimal patient comfort while maintaining clinical efficiency. The uncuffed design reduces pressure on the tracheal wall, making it suitable for patients who do not require a sealed airway. The fenestrations promote airflow to the vocal cords, supporting speech and improving patient quality of life.

The wedge-shaped flange ensures a secure and stable fit against the neck, minimizing movement and reducing the risk of displacement. The included decan cap enables clinicians to assess a patients readiness for decannulation by allowing airflow through the natural airway. The PVC material offers smooth insertion and durability, making it suitable for both hospital and extended care environments.

Compatibility and Applications

The Smiths Medical 101/818/100 tracheostomy tube is compatible with standard 15 mm connectors, allowing seamless integration with ventilators, humidification systems, and oxygen delivery devices. It is widely used in critical care units, step-down units, rehabilitation centers, and home care settings.

This tube is particularly suitable for patients who are progressing toward spontaneous breathing and require a device that supports both ventilation and phonation. It is also appropriate for use in long-term airway management where patient comfort and communication are priorities.

Usage Guidelines

Insertion and management of this tracheostomy tube should be performed by trained healthcare professionals following established clinical protocols. Prior to insertion, ensure that the correct size has been selected based on patient anatomy and clinical requirements. Lubrication may be applied to facilitate smooth placement.

Once inserted, the tube should be secured using appropriate fixation methods to prevent displacement. Regular monitoring is essential to assess airway patency, patient comfort, and signs of irritation or infection. The fenestrated design should be used with caution in patients at risk of aspiration, and clinical judgment should guide its application.

The decan cap can be applied during weaning trials to evaluate the patients ability to breathe through the upper airway. Close supervision is required during these trials to ensure patient safety.

Certifications and Safety Standards

The Smiths Medical tracheostomy tube is manufactured in compliance with recognized international medical device standards. It meets stringent quality and safety requirements to ensure reliable performance in clinical settings. The materials used are biocompatible and tested for patient safety, minimizing the risk of adverse reactions.

Production processes adhere to regulatory guidelines, ensuring consistency, sterility, and traceability. Each unit is packaged to maintain sterility until point of use, supporting infection control protocols in healthcare environments.

Comparison with Competitors

Compared to standard non-fenestrated tracheostomy tubes, this model offers enhanced functionality by enabling airflow to the upper airway, which supports speech and more natural breathing patterns. The inclusion of a decan cap provides added value by facilitating weaning assessments without requiring additional accessories.

While some competing products may offer similar materials, the wedge flange design of this tube provides improved anatomical conformity and stability. Additionally, the balance between flexibility and durability in the PVC construction ensures both patient comfort and long-term usability.

Typical User Profile and Application Scenarios

This product is commonly used by respiratory therapists, intensivists, and nursing professionals managing patients with tracheostomies. It is ideal for adult patients who are stable enough to benefit from an uncuffed, fenestrated tube and are being considered for speech rehabilitation or decannulation.

Typical scenarios include post-intensive care recovery, chronic respiratory conditions requiring airway support, and rehabilitation phases where restoring normal breathing and communication is a priority. It is also suitable for home care settings where long-term management is required under professional supervision.

Best Practices for Use and Maintenance

Routine care of the tracheostomy tube is essential to maintain airway patency and prevent complications. Regular cleaning and suctioning should be performed as needed to remove secretions and reduce the risk of blockage. The stoma site should be inspected frequently for signs of infection, irritation, or pressure injury.

The tube should be replaced according to clinical guidelines or manufacturer recommendations. Proper hygiene practices, including handwashing and use of sterile equipment, should be followed during all handling procedures. When using the fenestrated feature, ensure alignment with the tracheal opening to maximize airflow efficiency.

Regulatory and Safety Information

This device is intended for use by qualified healthcare professionals and should be used in accordance with established medical protocols. It is important to assess patient suitability before selecting a fenestrated, uncuffed tube, particularly in cases where airway protection is a concern.

Any signs of adverse reaction, including discomfort, bleeding, or difficulty breathing, should be addressed immediately. The product should not be reused unless explicitly specified, and all used devices must be disposed of according to local medical waste regulations.

How to Order

Select the Smiths Medical 101/818/100 Tracheostomy Tube, 10.0, Uncuffed, with Wedge and Decan Cap, Fenestrated, PVC,and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.