(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 103005 - Stylette Intubation 5.0-7.5 10/Ca

Smiths Medical # 103005 - Stylette Intubation 5.0-7.5 10/Ca
Part Number Smiths Medical 103005
SKU Number CIA1104615
Sell Unit CASE
Ships Within Special Order
List Price $47.89
Enter a valid quantity
Product Description

Smiths Medical 103005 - Stylette Intubation 5.0-7.5 10/Ca

The Smiths Medical 103005 Intubation Stylet is a precision-engineered airway management accessory designed to assist clinicians in guiding endotracheal tubes during intubation procedures. Suitable for tube sizes ranging from 5.0 mm to 7.5 mm, this malleable stylet provides the necessary rigidity and flexibility to shape and direct the tube for accurate placement. Each stylet is constructed with a durable internal core and a smooth outer sheath that minimizes friction and reduces the risk of tissue trauma.

Packaged conveniently in cases of 10 units, this product is ideal for hospitals, emergency departments, operating rooms, and critical care environments where reliable airway management tools are essential. Its ergonomic design and consistent performance make it a dependable choice for both routine and difficult intubations.

Key Benefits

The stylet offers excellent malleability, allowing clinicians to shape it according to patient anatomy and procedural requirements without compromising structural integrity. Its smooth outer coating facilitates easy insertion and removal, reducing resistance when navigating through the endotracheal tube.

The device enhances intubation precision, helping clinicians achieve proper tube placement more efficiently, which is critical in time-sensitive situations. Its compatibility with a common range of tube sizes ensures versatility across multiple patient groups, including pediatric and adult patients within the specified range.

Additionally, the product is designed for single use, supporting infection control protocols and minimizing cross-contamination risks in clinical settings.

Compatibility and Applications

The Smiths Medical 103005 Stylette is compatible with standard endotracheal tubes sized between 5.0 mm and 7.5 mm internal diameter. It is widely used in various medical environments, including operating rooms, emergency departments, intensive care units, and pre-hospital care settings.

This stylet is suitable for routine intubations as well as more complex airway management scenarios where additional control and guidance are required. It is commonly used by anesthesiologists, emergency physicians, respiratory therapists, paramedics, and critical care specialists.

Usage Guidelines

Before use, the stylet should be inserted into the endotracheal tube, ensuring that the distal tip of the stylet does not protrude beyond the tube tip. Clinicians can then shape the tube-stylet assembly to the desired curvature for optimal navigation through the airway.

During intubation, the assembly should be advanced carefully under direct or indirect visualization, depending on the technique being used. Once the tube is properly positioned, the stylet should be gently withdrawn while stabilizing the tube to maintain placement.

As a single-use device, the stylet should be disposed of according to clinical waste protocols after use. Reuse is not recommended.

Certifications and Safety Standards

The Smiths Medical 103005 Intubation Stylet is manufactured in compliance with internationally recognized medical device standards. It adheres to strict quality control processes to ensure consistent performance and patient safety.

The materials used are biocompatible and designed to meet regulatory requirements for medical devices used in airway management. The product supports healthcare facilities in maintaining compliance with infection prevention and control guidelines.

Comparison with Competitors

Compared to other intubation stylets available in the market, the Smiths Medical 103005 stands out for its balance of flexibility and firmness, allowing precise shaping without kinking or loss of form. Its smooth outer coating provides a lower friction experience than many standard stylets, improving ease of use during insertion and removal.

While some alternatives may offer similar functionality, this product delivers consistent quality backed by a well-established manufacturer known for reliability in airway management solutions. The standardized sizing and dependable performance make it a preferred option in clinical settings where predictability is critical.

Typical User Profile and Application Scenarios

This product is ideal for healthcare professionals involved in airway management, including anesthesiologists performing surgical intubations, emergency physicians managing acute airway compromise, and paramedics providing pre-hospital care.

It is frequently used in operating rooms for elective procedures, in emergency departments for urgent airway stabilization, and in intensive care units for ongoing respiratory support. The stylet is also valuable in teaching environments where trainees are learning intubation techniques and require reliable tools to build confidence and skill.

Best Practices for Use and Maintenance

To achieve optimal performance, clinicians should ensure that the stylet is shaped appropriately before insertion and that it remains fully enclosed within the endotracheal tube to prevent airway injury. Gentle handling during insertion and removal helps maintain patient safety and procedural efficiency.

As a single-use device, no maintenance is required. Proper disposal after each use is essential to maintain hygiene standards and comply with healthcare regulations. Storage should be in a clean, dry environment, away from direct sunlight and extreme temperatures, to preserve product integrity prior to use.

Regulatory and Safety Information

The Smiths Medical 103005 Intubation Stylet is intended for use by trained healthcare professionals only. It should be used in accordance with established clinical protocols and institutional guidelines for airway management.

Users should inspect the product prior to use to ensure there are no defects or damage. Any compromised devices should not be used. Proper training and adherence to recommended techniques are essential to minimize risks associated with intubation procedures.

How to Order

Select the Smiths Medical 103005 Stylette Intubation 5.0-7.5 10/Ca, and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products