-
Catheters (6,800+)
- Angiocatheters (50+)
- Closed System Catheters (300+)
- External Catheters (620+)
- Hydrophilic Catheters (140+)
- IV Catheters (1,200+)
- Non-Hydrophilic (20+)
- Plastic Catheters (200+)
- Rubber Catheters (700+)
- Silicone Catheters (770+)
- Ureteral Catheters (100+)
- Urethral Catheters (450+)
- Venous Catheters (240+)
-
Coronavirus (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (20,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Custom Kits
- Dental (14,000+)
- Gloves (8,000+)
-
Gynecology & Urology (1,000+)
- Bed Side Drainage Bags (350+)
- Circumcision (150+)
- Cord Clamps and Clippers (60+)
- Disposable Vaginal Specula (60+)
- Enema Bags (30+)
- External Catheters (620+)
- Foley Catheters and Trays (1,200+)
- Identification (1100+)
- Leg Bag Accessories (10+)
- Leg Bags (280+)
- Reusable Vaginal Specula (900+)
- Specimen Collection (200+)
- Tubing & Connectors (17,000+)
- Urinals / Bed Pans (1,300+)
- Urine Collectors (60+)
- Urological Irrigation Products (10+)
- Vaginal Specula Illumination (2+)
- Systems (11,000+)
- Hygiene (1,000+)
- Incontinence (1,000+)
-
Infection Control (2,500+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Iodine (460+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Infusion All (2,000+)
- IV Bags - Empty (300+)
- IV Bags - Filled (100+)
- Masks (3,800+)
-
Medical Apparel (23,000+)
- Arm Sleeves (240+)
- Beard Covers (20+)
- Bouffant Caps (200+)
- Compression Socks (80+)
- Coveralls (500+)
- Disposables (100+)
- Isolation Gowns (360+)
- Lab Coats (2,200+)
- Lab Jackets (300+)
- Patient Gowns (300+)
- Procedural Gowns (230+)
- Scrubs (20,000+)
- Shoe Covers (270+)
- Surgeon Caps (40+)
- Surgical Gowns (70+)
- Surgical Hoods (20+)
- Surgical Masks (330+)
- Ostomy (400+)
-
PPE (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (23,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Respiratory (500+)
- Sanitizer (600+)
- Surgical Supplies (14,000+)
- Sutures (7,500+)
- Syringes & Needles (14,000+)
-
Wound Care (5,000+)
- ABD Pads (100+)
- Adhesive Bandages (650+)
- Advanced Wound Care (400+)
- Applicators (6,700+)
- Burn care (240+)
- Dressings (7,500+)
- Elastic Bandages (1,600+)
- Gauze (3,300+)
- Ice / Heat Packs (280+)
- Medical Tape (820+)
- Non-Adhering Dressings (100+)
- Ointment & Solutions (450+)
- Self-Adherent Wraps (200+)
- Sponges (2,400+)
- Staple & Suture Removal (1,500+)
- Tegaderm (450+)
- Transparent Dressing (800+)
- Wound Care Prep (120+)
- Wound Cleansers (100+)
- Sales & Deals (100+)
- 3M (4,200+)
- Alaris Medical (600+)
- Amsino International (550+)
- Avanos Medical (40+)
- B Braun (1,500+)
- Baxter (750+)
- BD (2,800+)
- BSN Medical (2,000+)
- Cables & Sensors (3,200+)
- C.R. Bard (4,200+)
- Cardinal Health (6,800+)
- CareFusion (2,100+)
- ConMed (1,500+)
- Cook Medical (600+)
- Covidien (9,500+)
- DeRoyal (6,000+)
- Dukal (1,300+)
- Ethicon (4,100+)
- GE Healthcare (1,000+)
- Hartmann (600+)
- Hospira (530+)
- ICU Medical (1,700+)
- Masimo (170+)
- Medline (54,000+)
- Midmark (2,500+)
- Roche (300+)
- Smiths Medical (4,000+)
- Sunset Healthcare (450+)
- TrueCare Biomedix (20+)
- View All Brands (5,000+)
Smiths Medical 2010 - Medfusion 2010 Pump, Refurbished, Each
The Smiths Medical 2010 Medfusion 2010 Infusion Pump is a trusted, high-precision device designed to deliver controlled intravenous medications and fluids with exceptional accuracy. This refurbished unit offers healthcare facilities a cost-effective solution without compromising on performance or reliability. Built with advanced safety features and intuitive programming, the Medfusion 2010 pump supports a wide range of clinical environments including critical care, pediatrics, and general infusion therapy.
Known for its compact design and user-friendly interface, this infusion pump allows clinicians to manage complex infusion protocols with confidence. The refurbished version undergoes thorough inspection, testing, and calibration to ensure it meets stringent performance standards, making it a dependable option for both inpatient and outpatient care settings.
Key Benefits
The Medfusion 2010 infusion pump delivers consistent and precise fluid administration, reducing the risk of dosing errors and improving patient safety. Its programmable drug library enhances workflow efficiency by minimizing manual input and standardizing medication delivery protocols. The compact and lightweight design allows easy transport between departments, while the intuitive interface ensures quick adoption by clinical staff.
Refurbished units provide significant cost savings while maintaining high-quality performance, making them ideal for budget-conscious facilities seeking reliable infusion technology.
Compatibility and Applications
This infusion pump is compatible with a wide range of IV administration sets and accessories commonly used in healthcare environments. It is suitable for use in hospitals, ambulatory surgical centers, infusion clinics, and long-term care facilities. The Medfusion 2010 is particularly effective in pediatric and neonatal care, where precise low-rate infusions are critical.
Applications include medication delivery, hydration therapy, chemotherapy administration, and continuous infusion treatments requiring accurate flow control.
Usage Guidelines
Before use, ensure the device has been properly calibrated and tested according to facility protocols. Load the appropriate IV set securely and program the infusion parameters using the built-in interface. Verify all settings, including flow rate and volume to be infused, before initiating therapy.
Clinicians should regularly monitor the infusion process and respond promptly to any alerts or alarms generated by the pump. After use, clean and disinfect the unit according to infection control guidelines.
Certifications and Safety Standards
The Medfusion 2010 infusion pump is designed to meet recognized medical device safety and performance standards. Refurbished units are inspected and tested to ensure compliance with manufacturer specifications and industry regulations. Built-in safety features such as occlusion detection, air-in-line alarms, and programmable limits help protect patients and support safe clinical practice.
Comparison with Competitors
Compared to other infusion pumps in its category, the Medfusion 2010 stands out for its precision in low-flow rate delivery, making it particularly suitable for pediatric and neonatal care. Its intuitive interface reduces training time and minimizes user error, while the durable construction ensures long-term reliability.
Refurbished models provide a competitive advantage by offering premium functionality at a lower cost compared to new devices, without sacrificing performance or safety.
Typical User Profile and Application Scenarios
This product is ideal for healthcare providers including hospitals, outpatient clinics, and specialized care units that require accurate and reliable infusion therapy. It is frequently used by nurses, anesthesiologists, and infusion specialists managing critical care patients, pediatric cases, and long-term treatments.
Facilities looking to expand their equipment inventory while maintaining budget efficiency will find this refurbished pump particularly valuable.
Best Practices for Use and Maintenance
Regular maintenance and calibration are essential to ensure optimal performance. Follow manufacturer-recommended service intervals and conduct routine checks for accuracy and alarm functionality. Keep the device clean and free from contaminants, and store it in a secure, dry environment when not in use.
Proper staff training on device operation and troubleshooting will further enhance safety and efficiency in clinical settings.
Regulatory and Safety Information
This infusion pump is intended for use by trained healthcare professionals only. Users must adhere to all applicable clinical guidelines and institutional protocols. The device should be inspected prior to each use to confirm proper functioning. Any signs of malfunction should be reported and addressed immediately to prevent patient risk.
How to Order
To place an order for the Smiths Medical 2010 Medfusion 2010 Infusion Pump, contact CIA Medical directly at (312) 275-5850. Our team is available to assist with product details, availability, and bulk purchasing options tailored to your facilitys needs.
Soma Technology #2010, Medfusion 2010 Syringe Pump Refurb Ea
$1,646.68 EACH
Smiths Medical #MDX-003, Medfusion 3500 Syringe Infusion Pump with PharmGuard Medication Safety Software Refurbished, Each
Call for Pricing
Smiths Medical #2001, Medfusion 2001 Pump, Refurbished, Each
$1,293.50 EACH
Smiths Medical #2010I, Medfusion 2010I Pump, Refurbished, Each
$1,813.50 EACH