(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 21-4071-24 - TRAY PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 1.9MM OD POPYSULFONE/TITANIUM PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE DILATOR/INTRODUCER ASSEMBLY 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER P

Smiths Medical # 21-4071-24 - TRAY PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 1.9MM OD POPYSULFONE/TITANIUM PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE DILATOR/INTRODUCER ASSEMBLY 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER P
Part Number Smiths Medical 21-4071-24
SKU Number CIA1074168
Sell Unit EACH
Ships Within Special Order
List Price $402.54
Enter a valid quantity
Product Description

Smiths Medical 21-4071-24 - TRAY PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 1.9MM OD POPYSULFONE/TITANIUM PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE DILATOR/INTRODUCER ASSEMBLY 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER P

The Smiths Medical 21-4071-24 Port-A-Cath Tray is a comprehensive implantable vascular access solution designed for long-term intravenous therapy. This complete system features a single lumen, low-profile port constructed from durable polysulfone and titanium, paired with a 5.8 French, 76 cm polyurethane catheter. Engineered for reliability and patient comfort, the device supports consistent venous access for therapies such as chemotherapy, parenteral nutrition, and long-term medication delivery.

This tray is supplied as a fully integrated kit, including essential components such as a straight needle, vein pick, 18-gauge introducer needle, J guidewire, dilator and introducer assembly, 90-degree gripper needle, syringes, and a tunneler. The inclusion of these components ensures procedural efficiency and consistency, reducing the need for additional equipment during implantation. The low-profile design enhances patient comfort while maintaining optimal performance in clinical settings.

Key Benefits

The low-profile titanium port offers exceptional strength while minimizing visibility and discomfort under the skin. Its biocompatible construction reduces the risk of adverse reactions, making it suitable for extended implantation periods. The single lumen configuration simplifies access and maintenance, ensuring efficient delivery of fluids and medications.

The polyurethane catheter provides flexibility and kink resistance, allowing smooth navigation through the vascular system while maintaining consistent flow rates. The complete tray design minimizes preparation time for clinicians, supporting streamlined workflows in surgical and interventional environments. Each component is engineered for compatibility and precision, helping reduce procedural variability.

Compatibility and Applications

This Port-A-Cath system is widely used in oncology, hematology, and chronic care settings where repeated vascular access is required. It is compatible with standard infusion systems, syringes, and access needles commonly used in hospitals and outpatient clinics.

Typical applications include chemotherapy administration, long-term antibiotic therapy, blood sampling, and total parenteral nutrition. The device is also suitable for patients requiring frequent venous access while maintaining a discreet and low-maintenance solution.

Usage Guidelines

The device should be implanted by trained healthcare professionals following established sterile techniques and institutional protocols. Proper positioning of the catheter tip within the central venous system is essential to ensure optimal performance and reduce complications.

Access to the port should be performed using appropriate non-coring needles to preserve septum integrity. Regular flushing and maintenance protocols must be followed to prevent occlusion and maintain patency. Clinicians should monitor the site for any signs of infection, thrombosis, or mechanical issues throughout the duration of use.

Certifications and Safety Standards

The Smiths Medical Port-A-Cath Tray is manufactured in compliance with recognized international medical device standards. Materials such as titanium and polysulfone are selected for their proven biocompatibility and durability. The system adheres to stringent quality control processes to ensure safety, reliability, and consistent clinical performance.

Each component within the tray is sterile and intended for single use, minimizing the risk of cross-contamination. The product meets applicable regulatory requirements for implantable vascular access devices used in hospital and clinical environments.

Comparison with Competitors

Compared to alternative port systems, this device stands out for its comprehensive tray configuration, eliminating the need to source individual components separately. The use of a titanium port body provides enhanced durability compared to plastic-only alternatives, while the low-profile design improves patient comfort and cosmetic outcomes.

The polyurethane catheter offers a balance of flexibility and strength, outperforming more rigid materials that may increase the risk of vessel irritation. Additionally, the inclusion of advanced accessories such as the J guidewire and tunneler supports efficient and precise placement, giving clinicians greater control during the procedure.

Typical User Profile and Application Scenarios

This product is ideal for hospitals, surgical centers, oncology clinics, and interventional radiology departments. It is commonly used by surgeons, interventional radiologists, and vascular access specialists responsible for implanting long-term venous access devices.

Patients who benefit most from this system include those undergoing extended chemotherapy regimens, individuals requiring frequent blood draws, and patients receiving long-term intravenous therapies. The discreet design also supports improved quality of life by reducing the need for repeated peripheral venipuncture.

Best Practices for Use and Maintenance

To ensure optimal performance, healthcare providers should follow standardized flushing protocols using appropriate solutions after each use. Proper needle selection is critical to maintaining septum integrity and extending the lifespan of the port.

Routine inspection of the insertion site and device function is recommended to identify any early signs of complications. Maintaining strict aseptic technique during access and dressing changes significantly reduces the risk of infection. Proper documentation of device usage and maintenance activities further supports patient safety and continuity of care.

Regulatory and Safety Information

This device is intended for use by qualified medical professionals and should be handled in accordance with all applicable clinical guidelines. It is supplied sterile and must not be reused or re-sterilized. Any deviation from recommended usage may compromise device integrity and patient safety.

Clinicians should review all product instructions and institutional protocols before use. Any adverse events or complications should be reported in line with local regulatory requirements. Proper disposal of used components must follow established medical waste management procedures.

How to Order

To place an order for the Smiths Medical 21-4071-24 Port-A-Cath Tray, contact CIA Medicals customer service team for pricing, availability, and bulk purchasing options. This product is supplied as a complete tray to support efficient clinical use.

For assistance with ordering or product inquiries, please call (312) 275-5850 to speak with a knowledgeable representative who can help you select the right vascular access solution for your facility.

Related Products