Smiths Medical 21-4655-24 - TRAY PORT-A-CATH SINGLE LUMEN 1MM ID 1.9MM OD POPYSULFONE/TITANIUM PORT 7.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE DILATOR/INTRODUCER ASSEMBLY 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER TRACKIN

TRAY PORT-A-CATH SINGLE LUMEN 1MM ID 1.9MM OD POPYSULFONE/TITANIUM PORT 7.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE DILATOR/INTRODUCER ASSEMBLY 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER TRACKIN
Part Number Smiths Medical 21-4655-24
SKU Number CIA1074272
Sell Unit EACH
Ships Within Special Order
List Price $629.98
Enter a valid quantity
Product Description

Smiths Medical 21-4655-24 - TRAY PORT-A-CATH SINGLE LUMEN 1MM ID 1.9MM OD POPYSULFONE/TITANIUM PORT 7.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE DILATOR/INTRODUCER ASSEMBLY 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER TRACKIN

The Smiths Medical 21-4655-24 Port-A-Cath Single Lumen Tray is a comprehensive implantable venous access system designed for clinical procedures requiring reliable long-term vascular access. This tray includes a single lumen port with 1mm ID and 1.9mm OD dimensions, a polysulfone and titanium port body, and a 7.8FR 76cm polyurethane catheter. The system is supplied with essential procedural components, including straight and blunt needles, vein pick, 18GA introducer needle, J guidewire, dilator and introducer assembly, 90 degree needle, gripper needle, two syringes, tunneler, and tracking components.

Built for use in controlled healthcare environments, this Port-A-Cath tray supports efficient preparation and standardized placement workflows. Its single lumen configuration is suitable for therapies that require dependable central venous access while helping clinicians maintain procedural organization through an all-in-one tray format.

Key Benefits

  • Complete Port-A-Cath single lumen tray designed to support vascular access procedures.
  • Includes a 7.8FR 76cm polyurethane catheter for dependable venous access applications.
  • Polysulfone and titanium port construction supports durability and clinical reliability.
  • Single lumen design helps simplify access management for appropriate treatment protocols.
  • Tray format includes key accessories to support procedural efficiency and preparation.
  • Includes introducer, guidewire, dilator, tunneler, gripper needle, and syringe components for a more complete setup.
  • Suitable for healthcare facilities that require standardized implantable port access solutions.

Compatibility and Applications

The Smiths Medical 21-4655-24 Port-A-Cath Single Lumen Tray is intended for use by trained healthcare professionals in clinical settings where implantable venous access is required. It may be used in procedures involving long-term intermittent or continuous access to the vascular system, depending on facility protocols, patient needs, and clinician assessment.

This tray may be suitable for hospital departments, infusion centers, oncology services, interventional radiology settings, surgical units, and outpatient procedure centers that manage patients requiring reliable central venous access. Compatibility should always be confirmed against the facilitys clinical guidelines, approved protocols, and the manufacturers instructions for use.

Usage Guidelines

This product should be used only by licensed and trained medical professionals experienced in implantable venous access procedures. Before use, inspect the tray packaging and components to confirm that the product is intact, sterile where applicable, and within its stated expiration date. Do not use the product if the packaging is damaged, opened, or compromised.

Clinicians should follow the manufacturers instructions for use, institutional policies, aseptic technique, and applicable procedural standards. Proper catheter placement, flushing, port access, dressing, and maintenance procedures should be performed according to approved clinical protocols. Patient selection, access site determination, and procedural technique should be based on professional clinical judgment.

Certifications and Safety Standards

The Smiths Medical 21-4655-24 Port-A-Cath Single Lumen Tray is manufactured for professional medical use and should be handled in accordance with applicable healthcare regulations, facility requirements, and manufacturer guidance. Safety and performance depend on correct product selection, proper technique, appropriate patient assessment, and adherence to sterile procedure standards.

Healthcare teams should verify all labeling, packaging information, expiration dating, and product documentation before use. Any implantable venous access device should be managed with careful attention to infection prevention, catheter patency, secure access technique, and ongoing patient monitoring.

Comparison with Competitors

Compared with basic venous access kits or individual component ordering, the Smiths Medical 21-4655-24 tray offers the advantage of a comprehensive procedural setup in a single product configuration. The inclusion of a polysulfone and titanium port, polyurethane catheter, introducer components, guidewire, tunneler, gripper needle, and syringes can help reduce preparation time and improve procedural consistency.

For facilities that value organized tray-based workflows, this Port-A-Cath system provides a practical option over sourcing separate components. Its single lumen format may also be preferred where a straightforward implantable access solution is appropriate for the patients therapy plan.

Typical User Profile and Application Scenarios

This product is typically used by interventional radiologists, surgeons, oncology clinicians, vascular access specialists, infusion therapy teams, and trained nursing staff involved in the placement or management of implantable venous access devices. It is commonly selected by healthcare facilities that require dependable port access systems for patients who need repeated vascular access over time.

Application scenarios may include long-term infusion therapy, medication administration, blood sampling, oncology-related care, and other clinically approved uses where an implantable single lumen port is appropriate. Final product selection should be based on the patients treatment plan, vessel condition, access requirements, and the clinicians professional judgment.

Best Practices for Use and Maintenance

Use strict aseptic technique during handling, placement, access, and maintenance of the Port-A-Cath system. Confirm that all components are available before beginning the procedure, and maintain a sterile field throughout the process. Follow institutional procedures for catheter flushing, locking, dressing care, needle access, and infection prevention.

After placement, the port should be monitored according to clinical protocol for signs of infection, occlusion, migration, leakage, discomfort, swelling, or other complications. Staff responsible for accessing or maintaining the port should be trained in proper technique and should use only compatible access needles and approved supplies. Documentation of placement details, access events, maintenance, and patient response should be completed according to facility policy.

Regulatory and Safety Information

The Smiths Medical 21-4655-24 Port-A-Cath Single Lumen Tray is intended for professional healthcare use and should not be used without appropriate clinical training. This product must be used according to the manufacturers instructions for use and the healthcare facilitys approved procedures. Do not resterilize or reuse single-use components unless the product labeling specifically permits it.

Potential risks associated with implantable venous access devices may include infection, thrombosis, catheter occlusion, vessel injury, bleeding, migration, extravasation, and other procedure-related complications. Proper patient evaluation, placement technique, sterile handling, and ongoing maintenance are essential to safe and effective use.

How to Order

Select the Smiths Medical 21-4655-24 TRAY PORT-A-CATH SINGLE LUMEN 1MM ID 1.9MM OD POPYSULFONE/TITANIUM PORT 7.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE DILATOR/INTRODUCER ASSEMBLY 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER TRACKIN and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.