Smiths Medical 21-4183-24 - TRAY PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 1.9MM OD PLASTIC PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE VESSEL DILATOR 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER UNASSEMBLED

TRAY PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 1.9MM OD PLASTIC PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE VESSEL DILATOR 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER UNASSEMBLED
Part Number Smiths Medical 21-4183-24
SKU Number CIA1074207
Sell Unit EACH
Ships Within Special Order
List Price $402.54
Enter a valid quantity
Product Description

Smiths Medical 21-4183-24 - TRAY PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 1.9MM OD PLASTIC PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE VESSEL DILATOR 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER UNASSEMBLED

The Smiths Medical 21-4183-24 Port-A-Cath Single Lumen Low Profile Tray is a comprehensive implantable venous access tray designed for clinicians who require a compact, reliable, and procedurally efficient port system. This configuration includes a low profile plastic port, 1mm ID and 1.9mm OD catheter dimensions, a 5.8FR 76cm polyurethane catheter, and essential access and placement components for single lumen venous access procedures.

Designed for professional healthcare environments, this unassembled tray supports controlled placement, secure catheter positioning, and dependable vascular access when used according to facility protocol and clinician judgment. Its low profile design is suitable for patients who may benefit from a smaller implantable port option while maintaining practical performance for long-term infusion therapy, medication delivery, and blood withdrawal where clinically appropriate.

Key Benefits

  • Single lumen low profile port design supports streamlined venous access for appropriate infusion and therapy applications.
  • 5.8FR 76cm polyurethane catheter provides flexibility and durability for implantable vascular access procedures.
  • Compact plastic port construction is designed to reduce bulk while supporting dependable access performance.
  • Comprehensive tray configuration includes key procedural components such as introducer needle, J guidewire, vessel dilator, gripper needle, syringes, tunneler, vein pick, and straight/blunt needle.
  • Unassembled format allows clinicians to prepare and assemble the system according to procedural preference and institutional protocol.
  • Low profile design may support patient comfort and discreet placement when clinically suitable.

Compatibility and Applications

The Smiths Medical 21-4183-24 Port-A-Cath tray is intended for use by trained healthcare professionals in clinical settings requiring implantable single lumen venous access. It is commonly applicable in hospital, oncology, infusion therapy, interventional radiology, and surgical environments where long-term or repeated vascular access may be required.

This tray is designed for compatibility with appropriate port access needles, vascular access protocols, and infusion practices as determined by the treating clinician. The included 90 degree gripper needle supports port access after placement when used in accordance with product instructions, sterile technique, and facility guidelines.

Usage Guidelines

Use of the Smiths Medical 21-4183-24 Port-A-Cath tray should be limited to qualified clinicians trained in implantable venous access procedures. Before use, inspect the package integrity, verify the product reference, confirm expiration status, and ensure all required tray components are present and sterile.

The device should be prepared using aseptic technique and assembled according to the manufacturers instructions for use. Catheter placement, tunneling, port pocket creation, vessel access, guidewire use, dilation, flushing, and securement should follow accepted clinical practice and institutional policy. After placement, confirm catheter tip position and port function according to facility requirements before clinical use.

Certifications and Safety Standards

The Smiths Medical 21-4183-24 Port-A-Cath tray is manufactured for professional medical use and should be handled according to applicable healthcare regulations, institutional infection prevention standards, and sterile device handling procedures. Clinicians should refer to the manufacturers labeling, instructions for use, and facility policies for complete safety, storage, preparation, and disposal requirements.

As with all implantable vascular access devices, proper patient selection, sterile technique, correct placement, and ongoing monitoring are essential to reduce the risk of complications such as infection, thrombosis, catheter malposition, occlusion, leakage, or port access issues.

Comparison with Competitors

Compared with standard implantable port trays that may require separate sourcing of procedural accessories, the Smiths Medical 21-4183-24 tray provides a broad set of placement components in one organized configuration. The low profile plastic port, 5.8FR catheter size, and 76cm polyurethane catheter offer a practical balance of compact design, flexibility, and procedural utility.

Many competing port systems may vary in catheter material, port profile, included accessories, lumen design, or assembly requirements. This tray is particularly useful for facilities seeking a single lumen low profile port option with comprehensive procedural components while allowing clinicians to assemble the system according to their preferred workflow.

Typical User Profile and Application Scenarios

This product is typically used by vascular access specialists, surgeons, interventional radiologists, oncology clinicians, infusion therapy teams, and trained hospital staff involved in implantable port placement and maintenance. It may be selected for patients requiring repeated venous access for therapies such as chemotherapy, medication infusion, hydration, blood sampling, or other clinically indicated treatments.

The low profile design may be especially useful in situations where a smaller port profile is preferred, subject to the clinicians assessment of patient anatomy, therapy requirements, expected access frequency, and long-term care plan.

Best Practices for Use and Maintenance

Maintain strict sterile technique during preparation, placement, access, dressing changes, and ongoing care. Always verify compatibility of access needles and infusion components before use. Follow institutional protocols for flushing, locking, access needle changes, dressing maintenance, and monitoring for signs of infection or catheter-related complications.

Document the device details, placement site, catheter length, tip confirmation method, access status, and any procedural observations in the patient record. Inspect the port site regularly and educate the patient according to facility policy regarding signs and symptoms that should be reported promptly, including redness, swelling, pain, fever, drainage, or difficulty with infusion.

Regulatory and Safety Information

The Smiths Medical 21-4183-24 Port-A-Cath tray is intended for professional medical use only and should be used in accordance with the manufacturers instructions for use, applicable laws, and clinical standards. Do not use if the sterile barrier is compromised, the product is damaged, or the expiration date has passed.

All sharps and used components should be disposed of in approved medical waste containers according to facility, local, state, and federal requirements. The clinician is responsible for evaluating patient suitability, confirming correct placement, and managing device care according to accepted medical practice.

How to Order

Select the Smiths Medical 21-4183-24 TRAY PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 1.9MM OD PLASTIC PORT 5.8FR 76CM POLYURETHANE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE VESSEL DILATOR 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER UNASSEMBLED and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.