(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 21-7343-24 - CADD Administration Set, Includes: Bag Spike, Flow Stop, 1.2 Micron Air-Eliminating Filter, Clamp, Needleless Injection Site, One-Way Checkvalve with Male Luer, 114" Length, 15.5 ml PV, Not Made with DEHP, 15/bx

CADD Administration Set, Includes: Bag Spike, Flow Stop, 1.2 Micron Air-Eliminating Filter, Clamp, Needleless Injection Site, One-Way Checkvalve with Male Luer, 114
Part Number Smiths Medical 21-7343-24
SKU Number CIA8066893
Sell Unit BOX
Ships Within Special Order
List Price $388.71
Enter a valid quantity
Product Description

Smiths Medical 21-7343-24 - CADD Administration Set, Includes: Bag Spike, Flow Stop, 1.2 Micron Air-Eliminating Filter, Clamp, Needleless Injection Site, One-Way Checkvalve with Male Luer, 114" Length, 15.5 ml PV, Not Made with DEHP, 15/bx

The Smiths Medical 21-7343-24 CADD Administration Set is designed for controlled medication and fluid delivery with compatible CADD infusion systems. This administration set includes a bag spike, Flow Stop feature, 1.2 micron air-eliminating filter, clamp, needleless injection site, and a one-way check valve with male luer connection. With a 114 inch tubing length and 15.5 mL priming volume, it supports flexible clinical setup while helping maintain safe, reliable fluid administration.

Built for professional healthcare environments, this set is not made with DEHP and is supplied in a 15 per box configuration. It is suitable for facilities that require dependable infusion accessories for ambulatory, outpatient, home infusion, and clinical care settings where CADD pump compatibility is required.

Key Benefits

The Smiths Medical 21-7343-24 CADD Administration Set offers a practical combination of safety-focused components and efficient setup features. The integrated Flow Stop feature helps reduce the risk of unintended free flow when used according to the manufacturers instructions, while the 1.2 micron air-eliminating filter supports fluid pathway protection by helping remove air from the line.

The needleless injection site allows access without the use of a needle, supporting safer medication administration workflows. The one-way check valve with male luer connection helps promote directional flow control, while the bag spike provides a secure connection to compatible fluid containers. Its 114 inch length offers added flexibility for patient positioning and pump placement.

Compatibility and Applications

This administration set is intended for use with compatible CADD infusion systems and should be selected based on pump model, therapy requirements, facility protocol, and manufacturer guidance. It is commonly used in infusion therapy settings where controlled delivery, secure connections, and integrated filtration are required.

Typical applications may include ambulatory infusion, outpatient infusion therapy, specialty medication delivery, home healthcare infusion support, and clinical medication administration. The inclusion of a 1.2 micron air-eliminating filter makes it suitable for workflows where air management and line filtration are important considerations.

Usage Guidelines

Before use, confirm that the Smiths Medical 21-7343-24 CADD Administration Set is compatible with the intended CADD pump and prescribed therapy. Inspect the packaging before opening and do not use the product if the packaging is damaged, opened, or compromised. Follow facility protocol and the manufacturers instructions for priming, connection, pump loading, and line management.

Prime the set carefully to remove air from the tubing and confirm that all clamps, connectors, filters, and access points are functioning as expected before initiating therapy. The bag spike should be connected securely to the appropriate fluid container, and the male luer connection should be attached using proper aseptic technique. Monitor the infusion according to clinical policy and patient care requirements.

Certifications and Safety Standards

The Smiths Medical 21-7343-24 CADD Administration Set is manufactured for clinical infusion use and should be handled according to applicable healthcare standards, facility procedures, and manufacturer instructions. It is not made with DEHP, which supports facilities seeking DEHP-free administration set options for selected infusion protocols.

Healthcare professionals should verify product labeling, sterility status, expiration date, lot number, and compatibility before use. All use should align with institutional infection control practices, medication safety procedures, and applicable clinical guidelines.

Comparison with Competitors

Compared with basic infusion administration sets, the Smiths Medical 21-7343-24 CADD Administration Set provides a more specialized configuration for CADD pump workflows. Its combination of bag spike, Flow Stop feature, 1.2 micron air-eliminating filter, clamp, needleless injection site, and one-way check valve makes it suitable for infusion protocols that require more than standard tubing alone.

The 114 inch tubing length offers greater setup flexibility than shorter sets, while the 15.5 mL priming volume provides a defined fluid pathway capacity for clinical planning. The 15 per box packaging also supports inventory management for healthcare facilities, infusion centers, and home infusion providers that use CADD-compatible administration sets regularly.

Typical User Profile and Application Scenarios

This product is typically used by nurses, infusion specialists, pharmacists, home infusion providers, outpatient clinic teams, and hospital staff responsible for medication and fluid administration using compatible CADD systems. It is suitable for care environments where reliable pump administration, controlled flow, filtration, and secure line access are important.

Common scenarios include preparing an ambulatory infusion setup, connecting a medication bag to a compatible CADD pump, managing a filtered infusion line, supporting needleless medication access, or maintaining directional flow with an integrated check valve. It is also useful for facilities standardizing CADD administration supplies across multiple therapy programs.

Best Practices for Use and Maintenance

Store the Smiths Medical 21-7343-24 CADD Administration Set in a clean, dry environment and keep it in its original packaging until ready for use. Always check the product label, lot number, expiration date, and packaging integrity before opening. Use aseptic technique when handling connectors, injection sites, and fluid pathway components.

During setup, avoid kinking, pulling, or compressing the tubing, as this may affect flow performance. Confirm that the clamp and Flow Stop feature are positioned and functioning correctly according to the manufacturers instructions. Dispose of the set after use according to facility policy and applicable medical waste regulations.

Regulatory and Safety Information

The Smiths Medical 21-7343-24 CADD Administration Set is intended for professional healthcare use and should be used only by trained personnel or under appropriate clinical supervision. It should not be reused unless specifically indicated by the manufacturer, and it should not be used if packaging integrity has been compromised.

Users must follow all manufacturer instructions, facility protocols, medication administration policies, and infection prevention procedures. Product selection should be based on the prescribed therapy, pump compatibility, patient needs, and applicable clinical requirements. Any adverse event, device concern, or suspected malfunction should be handled according to institutional reporting procedures.

How to Order

Select the Smiths Medical 21-7343-24 CADD Administration Set, Includes: Bag Spike, Flow Stop, 1.2 Micron Air-Eliminating Filter, Clamp, Needleless Injection Site, One-Way Checkvalve with Male Luer, 114" Length, 15.5 ml PV, Not Made with DEHP, 15/bx, and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.