(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 21-7363-24 - CADD Administration Set, Includes: Bag Spike, Flow Stop, 1.2 Micron Air-Eliminating Filter, Spiral Tubing, Clamp, One-Way Checkvalve with Male Luer, 93" Length, 8.0 ml PV, Not Made with DEHP, 15/bx

CADD Administration Set, Includes: Bag Spike, Flow Stop, 1.2 Micron Air-Eliminating Filter, Spiral Tubing, Clamp, One-Way Checkvalve with Male Luer, 93
Part Number Smiths Medical 21-7363-24
SKU Number CIA8066894
Sell Unit BOX
Ships Within Special Order
List Price $372.01
Enter a valid quantity
Product Description

Smiths Medical 21-7363-24 - CADD Administration Set, Includes: Bag Spike, Flow Stop, 1.2 Micron Air-Eliminating Filter, Spiral Tubing, Clamp, One-Way Checkvalve with Male Luer, 93" Length, 8.0 ml PV, Not Made with DEHP, 15/bx

The Smiths Medical 21-7363-24 CADD Administration Set is designed for use with compatible CADD infusion pump systems where controlled fluid delivery, dependable connection, and medication pathway protection are required. This administration set includes a bag spike, Flow Stop feature, 1.2 micron air-eliminating filter, spiral tubing, clamp, one-way check valve with male luer, 93 inch tubing length, and 8.0 mL priming volume. It is supplied 15 per box and is not made with DEHP.

Built for clinical infusion workflows, this set supports safe and organized medication administration in settings where accuracy, patient safety, and line integrity are important. The integrated air-eliminating filter helps reduce the risk of air entering the fluid path, while the one-way check valve assists with controlled directional flow. Its 93 inch length provides practical flexibility for patient positioning, pump placement, and routine care activities.

Key Benefits

  • Designed for compatible CADD infusion pump applications requiring reliable administration set performance.
  • Includes a 1.2 micron air-eliminating filter to support safer fluid delivery and help manage air in the line.
  • Flow Stop feature helps reduce the risk of unintended free flow during setup, handling, or disconnection.
  • Bag spike supports secure connection to appropriate fluid containers used in infusion therapy.
  • Spiral tubing helps improve line flexibility and organization during patient care.
  • Clamp allows clinicians to control the line during priming, setup, medication changes, and discontinuation.
  • One-way check valve with male luer supports directional flow control and secure downstream connection.
  • 93 inch length provides practical reach for bedside, ambulatory, or home infusion positioning needs.
  • 8.0 mL priming volume supports efficient setup while maintaining a controlled fluid pathway.
  • Not made with DEHP, supporting facilities that prefer DEHP-free fluid pathway options.
  • Packaged 15 per box for clinical inventory management and repeat-use supply planning.

Compatibility and Applications

The Smiths Medical 21-7363-24 CADD Administration Set is intended for use with compatible CADD infusion systems and appropriate infusion protocols. It may be used in clinical environments where CADD pump-based medication delivery is required, including hospital departments, infusion centers, specialty pharmacy programs, outpatient care, and home infusion services under qualified clinical supervision.

This administration set is suitable for therapies that require controlled pump-assisted delivery through a filtered fluid pathway. The 1.2 micron air-eliminating filter is especially useful in applications where filtration and air management are part of the prescribed infusion setup. The bag spike connection makes the set appropriate for compatible bag-based infusion containers, while the male luer and check valve support secure connection to the patient access pathway or extension configuration as directed by facility protocol.

Usage Guidelines

Use the Smiths Medical 21-7363-24 CADD Administration Set only with compatible CADD pump systems and in accordance with the pump manufacturers instructions, medication labeling, facility policy, and clinician-approved infusion orders. Before use, confirm that the packaging is intact, the set is within its acceptable use date, and all components are present.

Prime the administration set according to the approved procedure before connecting it to the patient. Ensure the bag spike is properly seated in the compatible fluid container, the clamp is positioned as required, and the Flow Stop feature is functioning as intended during setup. Confirm that the 1.2 micron air-eliminating filter is correctly oriented and free from visible blockage. The one-way check valve should be checked for proper directional connection before infusion begins.

During therapy, monitor the infusion system, fluid pathway, access site, and pump alerts according to clinical protocol. Do not reuse the set if it is intended for single-patient or single-use application. Replace the administration set according to facility policy, medication requirements, and infection control standards.

Certifications and Safety Standards

The Smiths Medical 21-7363-24 CADD Administration Set is manufactured for professional healthcare use and should be handled according to applicable medical device standards, institutional policies, and infection prevention procedures. Its not made with DEHP construction supports clinical environments that require or prefer DEHP-free administration components.

The included 1.2 micron air-eliminating filter supports fluid pathway safety by helping manage particulate filtration and air removal within the line. The Flow Stop feature, clamp, and one-way check valve add important control points that assist clinicians in reducing unintended flow risks and maintaining a more secure infusion setup.

Comparison with Competitors

Compared with standard gravity or basic pump tubing sets, the Smiths Medical 21-7363-24 CADD Administration Set provides a more specialized configuration for CADD pump-based infusion therapy. Its combination of a bag spike, Flow Stop feature, air-eliminating filter, spiral tubing, clamp, one-way check valve, and male luer connection makes it a comprehensive option for controlled infusion workflows.

Many general administration sets may not include an integrated 1.2 micron air-eliminating filter or Flow Stop protection. This set is designed for facilities and care teams that require a compatible CADD administration set with built-in safety and connection features. The 93 inch length also offers more practical reach than shorter configurations, helping reduce strain on the line during bedside care, ambulatory therapy, or home infusion use.

Typical User Profile and Application Scenarios

This product is commonly used by infusion nurses, hospital clinicians, home infusion providers, specialty pharmacy teams, and outpatient infusion centers that manage pump-assisted therapies with CADD systems. It is appropriate for care environments where clinicians need a reliable, filtered administration set with secure connections and controlled flow features.

Typical scenarios include preparing medication for pump-based infusion, connecting a compatible infusion bag to a CADD pump, supporting filtered infusion pathways, managing ambulatory pump setups, and maintaining controlled medication delivery in professional or supervised home care settings. The 15 per box packaging makes it suitable for departments or providers that require consistent supply availability for recurring infusion needs.

Best Practices for Use and Maintenance

Store the Smiths Medical 21-7363-24 CADD Administration Set in a clean, dry area away from excessive heat, moisture, and direct sunlight. Keep the product in its original packaging until ready for use to help maintain cleanliness and product integrity.

Before each use, inspect the set for damage, kinks, loose connections, compromised packaging, or visible contamination. Follow the recommended priming process carefully to remove air from the fluid pathway and confirm that the filter and tubing are functioning properly. Secure all luer connections without over-tightening, and ensure the tubing is routed to avoid pulling, compression, or accidental disconnection.

Dispose of used administration sets according to facility procedures and applicable medical waste guidelines. Do not attempt to clean, resterilize, or reuse the set unless the manufacturers instructions and facility policy specifically allow it.

Regulatory and Safety Information

The Smiths Medical 21-7363-24 CADD Administration Set should be used only by trained healthcare professionals or properly instructed caregivers under clinical direction. It is intended for use with compatible CADD infusion systems and should not be substituted for unrelated administration sets unless compatibility has been verified.

Always follow medication-specific administration requirements, pump instructions, facility protocols, and patient monitoring guidelines. Incorrect setup, incomplete priming, incompatible connections, or failure to monitor the infusion may increase the risk of therapy interruption, air-in-line alarms, occlusion, leakage, or inaccurate medication delivery. If resistance, leakage, pump alarm, filter blockage, or patient discomfort occurs, stop and evaluate the system according to clinical procedure.

How to Order

Select the Smiths Medical 21-7363-24 CADD Administration Set, Includes: Bag Spike, Flow Stop, 1.2 Micron Air-Eliminating Filter, Spiral Tubing, Clamp, One-Way Checkvalve with Male Luer, 93" Length, 8.0 ml PV, Not Made with DEHP, 15/bx and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products